Marc-André Bombeck 6026a28fe4 fix(dashboard): key streak and compliance days in the person's own zone
`measured_at` and `scheduled_for` are naive UTC timestamps. The dashboard
streak and the medication-compliance backfill keyed them with a single
`AT TIME ZONE tz`, which reads the value as local time and shifts it the
wrong way: in Berlin a reading at 23:30 UTC counted for the day before
instead of the day after, so a streak could break or stretch near
midnight and the backfill recomputed the wrong day.

The streak's measurement days now come from `readActivityDayKeys`: one
existence probe per local day instead of a DISTINCT over a year of
readings. The DAY rollups cannot answer this because their buckets are
UTC days. The two compliance-rollup readers had no caller left and are
removed with the coverage probe that carried the same shift. A guard
fails on any single shift of a naive column into a bound zone.