mirror of
https://github.com/MBombeck/HealthLog.git
synced 2026-11-08 20:42:43 +00:00
The oxygen saturation page drew a fixed clinical band, so a person with a lower target of their own saw their normal range shaded as a warning. The page now reads the resolved range from /api/user/thresholds and draws it; without a target the clinical bands stay as they were. Refs #1261