- Reword the upload toasts to the store-only reality ("stored", not "read"),
so the success message no longer claims AI ran and the panel it opens no
longer contradicts it.
- Classify upload failures (too large / wrong type / rate-limited / invalid
metadata) into specific messages; add a client-side 12 MB pre-check and show
the accepted formats and size ceiling beside the file field.
- Clear filters, search, and sort on a successful upload so the new document is
in the list the detail panel opens against, and add a "Clear filters" action
on the no-results state.
- List approved facts read-only after review so the link between a document and
the records it contributed stays visible instead of "Nothing left to review".
- Format date-group headers through the app's own date formatter, so they honour
the user's date-format preference instead of a textual medium style.
- Stack the toolbar until md and let it wrap; wrap the fact badge row on narrow
screens.
- Tie the disabled Approve to a plain-language reason, label the confidence
percentage, and render it through the locale percent formatter.
- Treat a fully-confirmed re-extract (422) as the calm already-reviewed note,
matching the partly-confirmed case.
- German: unify on "Angaben" for the extracted items and drop the anglicism.
Tighten the documents library review surface after a QA pass:
- Surface the provider-unsupported and already-confirmed notes as polite
live regions (role=status / aria-live) so keyboard and screen-reader
users hear them when the suppressed-toast paths fire.
- Render a document's detail panel directly after the row that opened it,
and tie the row's aria-controls to the panel id, fixing reading and
tab order.
- Gate Discard behind a confirm dialog and toast on failure.
- Disable Upload until a file is chosen, with an inline hint.
- Namespace per-fact editor field ids so simultaneously-open editors no
longer share DOM ids (label-for associations stay correct).
- Hide Extract once any fact is approved, mirroring the server guard, and
treat the already-confirmed response as a calm inline note.
- Add a document-date range filter, a kind fallback for the detail title,
and a screen-reader hint on the new-tab original link.
- Calmer, neutral needs-review badge and more legible row badges.
Adds the new strings across all six locales.
Evolve the inbound-documents screen into a real document library on top of
the store-first backend.
- Upload stays store-only and always works: the form now files a document
with an optional title, category, and document date in one step. Extraction
is a separate, explicit action.
- List becomes an organized library: documents grouped by date, with a title
(filename fallback), category and status badges, and pending/fact counts. A
toolbar adds title/filename search, a category filter, and a sort control
(document date / date added / title, asc/desc). Keyset pagination loads more
via the returned cursor through useInfiniteQuery.
- Detail panel: view or download the original, edit metadata (rename,
recategorise, set the document date), optionally run extraction, then the
existing review-then-confirm flow. When no scan provider is configured,
extraction surfaces a calm inline note instead of a hard error; the stored
document is untouched. Discard stays.
- Add a parameterised list key to the query-key factory so each filter/sort
combination keeps its own cache bucket while staying under the documents
prefix for invalidation.
- Rename the surface to "Documents" across all six locales (title, subtitle,
module label/description) and add the new toolbar, edit, extract, and
date-group strings. Route, model, and module key stay internal.
Add component and unit coverage for the grouped list, the detail/review
surface, the metadata edit form, the provider-unsupported note, and the
search-param/grouping/error-classification helpers.
Remove the standalone amber disclaimer card from the inbound-documents
review screen. The non-diagnostic essence now reads as the plain muted
subtitle line under the page title: upload a clinical document and review
the extracted details. Drop the now-unused disclaimer.title /
disclaimer.body keys across all six locales and the AlertTriangle /
CardDescription imports left orphaned by the removal.
The inbound-document store keeps the uploaded doctor letter encrypted at
rest (InboundDocument.contentEncrypted, AES-256-GCM), but there was no way
to read the original back — the decrypt helper had been dropped as unused.
- Restore decryptDocumentFromBytes in the document store, fail-closed on a
bad / missing key id.
- Add GET /api/documents/inbound/[id]/original: owner-scoped (userId-narrowed
query), module-gated, returns the decrypted bytes with the stored MIME
type. A PDF / image is served inline so the browser can render it; other
types download as an attachment. The filename is sanitised before it
reaches the Content-Disposition header. The bytes are PHI — never logged,
never served cross-user, and a decrypt error fails closed (500) rather than
returning ciphertext. Cache-Control is private, no-store.
- Surface a 'View original' action in the document review screen.
- Document the route in the OpenAPI registry and regenerate the spec.
- Cover the route with a test: owner-scoped success, attachment fallback,
404 for another user's document, and fail-closed on decrypt error.
i18n: viewOriginal across all six locales.
The inbound-document list and review panels used centered spinners; swap
them for the app's Skeleton pattern so the resolved content lands without
a layout jump. The low-confidence review badge moves from destructive red
to a calm amber, matching the surface's non-alarming posture. Approve /
reject / edit / save controls grow to the 44px touch floor, the upload
file input gains an accessible label, and each document row exposes
aria-expanded.
Add the opt-in inboundDocuments module (off by default, like the MCP
endpoint): ingesting a clinical document egresses it to the OCR/vision
provider, so the surface ships dark and the user turns it on from the
Modules hub. The born-gated /documents page carries the prominent
non-diagnostic disclaimer (we read, we don't interpret; nothing is saved
until you approve it; only your clinician can interpret these results),
uploads a document, and walks each extracted fact: source provenance and
confidence are shown, low-confidence facts are blocked from approval until
edited, and the confirm step commits the approved facts.