Commit Graph
152 Commits
Author SHA1 Message Date
Marc-André Bombeck e91957c017 fix(labs): word a three-year projection horizon as the cap it is
The beyond-horizon line said the range held "for more than {years}
years, the span your readings cover", but the horizon is capped at three
years, so a ten-year history was told its readings spanned three. The
trend now says whether the cap or the span set the horizon
(`horizonCapped`), and the card words each case on its own in every
locale.
2026-10-22 00:32:13 +02:00
Marc-André Bombeck e482f76508 fix(labs): stop projecting lab trends from stale or short series
A marker whose newest reading is more than a year old is now reported
as of that reading (projection "stale"), with no exit date and no
already-outside verdict. The projection horizon is capped at the span
the readings cover, so a line is never carried further ahead than the
data reaches back. The detail read keeps the newest 2000 readings
rather than the oldest.
2026-10-21 22:40:43 +02:00
Marc-André Bombeck 2ba6214a65 feat(labs): show each marker's slope and where the line would leave the range
The biomarker detail read now carries a trend: the least-squares line
through every numeric reading of the marker (all stored in its unit), with
the slope's 95 % interval and p-value. It needs three readings over at
least a year. The line is placed against the marker's band, and an exit
date is given only when the interval excludes zero, the line is inside the
band today and reaches a bound within three years. The detail page words
it as a straight-line projection, not a forecast.
2026-10-21 21:51:36 +02:00
Marc-André Bombeck 71dbef1742 feat(settings): nine groups, module pages and one switch per state
Settings now reads as nine groups: Account, Tracking, Arrangement,
Notifications, Health profile, AI, Connections, Data and System. On a
phone one button names the current section and opens the grouped list,
replacing the strip of every section.

What moved, every old address still working:
- Sessions, trusted devices and security activity sit under Security;
  the privacy page anchors forward there.
- Notifications holds every reminder kind: the Coach nudges and the
  checkup reminder switches joined, and a card names the reminders set
  where their subject lives (dose times, cycle reminders).
- Arrangement holds order and view only. Mood tags, the labs biomarker
  catalog and on-device text recognition, and the injection sites live on
  module pages under /settings/modules/<id>, linked from each Modules row
  and from the module's own wrench. /settings/layout/mood redirects.
- The timezone saves on change in the Display card, with a one-tap offer
  of the device zone.
- Screening hints sit beside the life circumstances they come from.
- System gains Preview features with the Topics switch.

Duplicates: the Coach and MCP pages show their state and link to the one
switch in Modules (turning MCP off keeps tokens), the Coach overlay shows
the provider and model with a link to Settings > AI instead of a second
set of selects, and the privacy page drops its copy of the export links.

A guard walks every historical /settings address through the redirects
and every forwarded anchor to a page that renders.
2026-10-21 19:43:02 +02:00
Marc-André Bombeck eabfeaef08 Merge branch 'fix/v14311-settings' into release/v1.43.11
# Conflicts:
#	messages/de.json
#	messages/en.json
#	messages/es.json
#	messages/fr.json
#	messages/it.json
#	messages/ko.json
#	messages/nl.json
#	messages/pl.json
2026-10-21 14:13:51 +02:00
Marc-André Bombeck 2bb3783b14 fix(settings): report the outcome of quiet settings actions
Adding or removing a passkey or a security key only redrew the list.
Disconnecting an integration and revoking a share link ran from a dialog
that had already closed, so a refused request left everything as it was
without a word. The injection-site exclusions, the local OCR switch and
the preventive-care reminder switches saved, or did not, in silence.

Each now reports through the outcome toast and, where the card has no
inline error line, the shared error toast with its error id.
2026-10-21 12:36:14 +02:00
Marc-André Bombeck 4c50f48b26 fix(labs): name a failed re-check as an error and close the last budget gaps
A re-check or reservation that failed itself stopped the scan as
"unavailable", and the review screen said AI had been turned off. It now
stops as stoppedBy error with its own message in every locale, and the
failure is reported as one: an error signal and the worker error
reporter. A scan that failed that way before any row answers 500
aiRuns.failed.

The overspend booked before a further read is now net of the cached
share, as the settlement books it. A reservation that names no known
owner stops the scan instead of taking the user plan's larger cap.

A page's text layer is cut at the last whole line; only a page whose
first line alone runs past the cap keeps part of it, cut at a space or
hard, rather than collapsing to the bare cut mark, and an endless line is
no longer read past the cap. The unused per-call text limit is gone. The
run result's description names every outcome a stopped scan can have.
2026-10-21 12:28:32 +02:00
Marc-André Bombeck 79d905f089 fix(labs): reserve and re-check each page of a scan, and read digits from the text layer
The route reserved one read's budget and checked the wire once, and a
20-page report then ran up to 40 calls for many minutes on that single
admission. Every read after the first now reserves its own share of the
day's budget and asks the wire again (aiEgressRefusal) before it is sent;
when either refuses, the scan stops there, keeps the pages already read
and names the rest with stoppedBy budget or unavailable. The run settles
against everything it reserved, with the provider's reported usage net of
its cached share, and a scan that fails after several calls is charged
for them instead of refunded in full.

A rendered PDF page now goes out with its own text layer, read by pdfjs
beside the image, so a digitally produced report's digits, decimal
separators and units come from its characters rather than from a 1600 px
picture. Splitting the PDF into single-page documents would need a PDF
writer the project does not ship; the text layer needs none and helps
every provider. A scanned page has no text layer and reads as before.

Codex's cut reply keeps the text it streamed (on a non-enumerable
property, so no log or event serialises it), and its closed rows are
salvaged like every other provider's. The merge folds a reading only into
one an earlier page listed, never two rows of the same page, and the
printed range is part of the key. OCR'd text the deadline cannot split
small enough for one read is refused up front as labs.ocr.tooLarge.
2026-10-21 11:10:02 +02:00
Marc-André Bombeck 6376710254 fix(labs): say on the review screen what a scan could not read
The review screen now names a read that stopped at the provider's output
limit (the pages it happened on, or the report when it was one read),
pages the provider never answered for, and a report with more readings
than one scan carries, beside the existing page note. A scan that
produced no reading because every read hit the output limit says so
instead of asking for a clearer photo.

A scanned name or result longer than 120 characters, or a unit longer
than 40, now marks its field on the row instead of failing the whole
save with a 422; the commit's bounds are shared with the screen.
2026-10-21 10:43:04 +02:00
Marc-André Bombeck f9796858e6 fix(ui): give the segmented control back the chart tabs' look
The shared control introduced a muted track with the chosen segment
raised on the background colour. In a chart header it read heavier than
the card around it, larger type and wider segments on a grey bar, and it
dropped the primary fill the range tabs had carried.

Segmented now draws the chart tabs' former look everywhere: no track, the
chosen segment filled in the primary colour, the others plain until
hovered. A small size keeps the range rows in chart headers at the former
type and padding; the touch floor of 44 px on a coarse pointer stays.
2026-10-21 09:32:58 +02:00
Marc-André Bombeck 7ed953a029 fix(ui): route the hand-built segment rows through Segmented
The narrative period, the lab result type, both admin filters, the chart
range tabs, the mood chart's own copy of them, the sleep-stage window and
the re-authentication method each spelled a segmented control by hand,
with their own sizes and fills. They render Segmented now; the range tabs
keep their long names as a hover title, and the admin filters gain an
accessible group name in every language. A test refuses a new button row
whose aria-pressed compares a state to each button's value, and names
the rows that remain with why they are not one choice on one track.
2026-10-20 16:43:59 +02:00
Marc-André Bombeck e7ee416e19 refactor(ui): move 62 hand-written empty states onto EmptyState
The admin sections, the cycle, illness, medication, mood, records and
settings cards, the pickers and dialogs said nothing-here-yet in a
hand-written muted paragraph in five sizes and three alignments. List
and section states now render through EmptyState (plain, compact; the
three with a next step carry it as the action), and the six chart
bodies through ChartEmptyState at their former height. The thirteen
that stay are a field without a value or a hint inside an editor, not
a list state. The ratchet ceiling drops from 75 to 13.
2026-10-20 13:31:02 +02:00
Marc-André Bombeck ee2bc8019c feat(ui): ScorePill for every grade chip
Confidence levels, the weekly score gain, target bands and lab range
flags were drawn by hand in two looks: a /15 wash without border in the
mood boards, a /10 wash with a /40 border on the correlation and trend
cards, and medium confidence was blue on one card and amber on the
next. They now render through one ScorePill (rounded, xs, soft wash,
tone success / info / warning / destructive / neutral, optional tabular
figures) with one confidence scale. The target band keeps its own
AA-tuned tokens in the shared anatomy. A structural test refuses a new
hand-rolled grade chip.
2026-10-20 13:24:00 +02:00
Marc-André Bombeck ff583104a8 fix(ui): wrap lab names and token names between words
The lab list wrapped a long analyte name with overflow-wrap: anywhere,
which cut a word that would have fit on the next line in the middle
(Hämo|globin). It now wraps between words and hyphenates in the page
language, cutting only a word wider than the column. Token and client
names in the API and MCP settings used break-all for the same reason
and now wrap the same way; addresses and codes keep break-all.
2026-10-20 13:15:28 +02:00
Marc-André Bombeck 537bad4212 fix(ui): print every displayed decimal in the reader's notation
toFixed() prints a full stop in every language and a locale-less
toLocaleString() follows the browser, so a German reader saw 37.5 next
to 70,5 on the same screen. Fever in the illness log, the cycle phase
crosstab, custom metric values, nutrient day totals, the mood chart and
heatmap tooltips, the mood takeaways, the elevation chart axis, the BP
30-day average, the host metrics clock and the encryption row counts now
go through useFormatters().

The new healthlog/no-unlocalised-decimal rule refuses toFixed(),
toPrecision(), a locale-less toLocaleString() or Intl constructor, and a
quotient rendered straight into text under src/components and src/app.
Rounding through Number(...) stays legal; SVG path data and number-input
values carry a reasoned next-line directive.
2026-10-20 12:55:07 +02:00
Marc-André Bombeck fea1d1e0b5 chore: strip planning tags from comments and enable the rule
Output of `node scripts/strip-planning-tags.mjs --write`: 3,157 comment
lines in 1,308 files lose the work-item identifier at their head. Release
versions and issue references stay; nothing outside comment text
changes, which the script checks per file against a comment-free
printout. healthlog/no-planning-tags is enabled at error level with this
commit, so the tree it lands on is clean.
2026-10-20 09:08:40 +02:00
Marc-André Bombeck 9b93247ae0 test: prime only the EN catalog in the unit setup
The setup file runs once per test file and imported all eight message
catalogs, several hundred kilobytes each, which made setup the largest
share of a component-suite run. It now primes EN, the fallback floor of
the t() chain. A test that renders another locale primes it at module
scope through primeLocales(), which loads the catalog via the production
loader in a file-level beforeAll.
2026-10-20 08:38:08 +02:00
Marc-André Bombeck 3cf67d05f9 fix(ui): let the read-failure primitives decide by the error
About forty compact rows and seventy cards still offered a retry on a
spent read budget and drew an error card on a refusal, while a third
primitive (ReadFailureRow) did the right thing at eight places.

QueryErrorRow and QueryErrorCard now take the query's `error` and read
it through readFailureKind, which moves to src/lib/api next to
ApiError: a refusal (403) draws the surface's refused state or nothing,
a spent budget (429) says so without a retry, an ended session (401)
says so and offers sign-in instead of going blank, and only a real
failure offers the retry. ReadFailureRow is gone and every site passes
its error; a guard test fails on a site that does not.

The coach read strip keeps its card in the error state and holds one
body height across loading, failure and a one-line read.
2026-10-20 03:38:57 +02:00
Marc-André Bombeck 0ee7e156d3 fix(report): print lab values with the precision they were recorded at
The doctor report PDF printed lab values and reference ranges with one
decimal and the share page with two at most, so a PSA of 0.034 read 0.0
or 0.03 and a TSH window of 0.27 read 0.3, while the labs page kept more.
The labs page itself cut values above 1 to two decimals.

One rule now decides every recorded number (src/lib/format/recorded-number):
a stored value keeps every digit it holds, minus binary float noise, and a
value converted from the unit its report printed keeps the precision of the
printed figure. The report payload carries sourceValue for that. The labs
page, its chart and history, the PDF lab table and footnote, the share
page, the day view and the OCR review all print through it, reference
bounds included. Doses on the PDF and the share page follow the same rule.

Measurement statistics in the PDF and on the share page now share one
per-row precision: up to three significant digits but never more decimals
than recorded, so a waist-to-height ratio of 0.52 no longer reads 0.5;
glucose keeps its unit's precision.

Refs #1228
2026-10-16 11:00:27 +02:00
Marc-André Bombeck da1d31e370 feat(labs): show and file a reading's related report and visit in its sheet 2026-10-16 05:34:08 +02:00
Marc-André Bombeck 326619069b fix: route the AI usage and lab merge error toasts through the error-id helper 2026-10-15 23:16:52 +02:00
Marc-André Bombeck 74fa4e10b6 Merge branch 'v143/labs' into release/v1.43.0 2026-10-15 23:06:51 +02:00
Marc-André Bombeck e112e05a58 fix(labs): name a merge in the owner's activity feed and toast it through the outcome module
A merge by a record manager now reads as its own sentence in the owner's
activity feed, the merged toast goes through the written-outcome toast,
and the export test doubles carry the alias and merge tables.
2026-10-15 23:03:45 +02:00
Marc-André Bombeck e65ada2961 feat(labs): merge markers, edit their aliases and pick a marker on review
The marker list offers a merge with the server's preview: what moves, what
is converted, which names become aliases, and a refusal when a unit cannot
be converted; it says a merge cannot be undone. The marker page shows and
edits the other spellings and follows a merged marker to its target. Scan
and document review name the matched marker or offer its suggestions and a
new marker; the choice is remembered. The biomarkerMerge feature flag is
on.
2026-10-15 22:55:08 +02:00
Marc-André Bombeck 6979928d73 chore(web): drop toast imports the error toast helper made unused 2026-10-15 22:36:34 +02:00
Marc-André Bombeck f7386742b4 feat(web): show the error id on server failures and add the support info and report surfaces 2026-10-15 22:31:51 +02:00
Marc-André Bombeck 81be73fca8 feat(labs): merge markers, keep aliases and read lab series per marker
POST /api/biomarkers/{id}/merge folds markers into one in a transaction,
converting readings where the registry knows the units and refusing the
whole merge where it does not; a dry run answers the same result and
writes nothing. Aliases appear on the marker and are edited through the
marker's PUT. Scan and document review rows name the matched marker or
offer up to three, and a chosen marker is remembered as an alias. The
doctor report, FHIR and MCP group readings by marker. Aliases and the
merge ledger travel through backup and restore.
2026-10-15 22:22:40 +02:00
Marc-André Bombeck 53e60f43f1 feat(labs): list every marker from a server-side per-biomarker overview 2026-10-15 15:03:06 +02:00
Marc-André Bombeck 07d991adf7 fix(labs): keep the value and draw-date column inside the dialog body
The single-column grid used the implicit auto track, which grows to the
widest cell's min-content. The draw date's date and time inputs size
from the font, so with wider metrics that min-content passed the dialog
body (about 422 px against 398 px) and the value input ran 24 px into
the dialog's padding. An explicit grid-cols-1 track is minmax(0, 1fr)
and stays at the body's width; the date row already shrinks inside it.

Refs #1214
2026-10-14 21:01:13 +02:00
Marc-André Bombeck 42b66b2228 Merge branch 'v1423/labs' into release/v1.42.3 2026-10-14 19:34:44 +02:00
Marc-André Bombeck eabbe3e032 fix(labs): let the conversion badge in the scan review wrap
At 390 px the badge truncated, and the part it cut off was the value the
report printed. It now wraps inside the row like a sentence.
2026-10-14 19:19:44 +02:00
Marc-André Bombeck 07f09e1b61 fix(labs): store the catalog slug as a marker's analyte key
The matcher stored the registry entry's key, so LDL and HDL markers were
recorded as total-cholesterol. The key now names what the marker is (the
catalog slug, or a registry-only key for an analyte with no seed), and the
registry resolves ldl and hdl to the cholesterol entry for the conversion as
before. A key already written in the old form is rewritten by the same fill
step that brings a stale key in line with its name, the first time a reading
needs it. The OpenAPI descriptions say what the key is and that it follows
the marker's name and unit.
2026-10-14 19:18:49 +02:00
Marc-André Bombeck cd1449e63e fix(labs): keep a reading's conversion record unless its value actually changes
The single-reading edit cleared sourceValue and sourceUnit whenever the body
carried a value, and the web edit sheet always sends one, so a date or note
edit erased the "converted from" hint. It is now cleared only when the value
differs from the stored one. The sheet also opened a converted reading at its
stored precision (100.90191999999999); it now starts from the value as the lab
surfaces show it and leaves an untouched value out of the request, so the
stored full-precision number is not replaced by its rounded display.
2026-10-14 19:15:33 +02:00
Marc-André Bombeck 47a91d6922 fix(labs): never present a converted reading's printed range in the wrong unit
A converted reading's bounds move with its value, but the printed range text
stays in the unit the report used, and every reader preferred that text: the
list showed "Report range 3.9 to 5.5" beside 100.9 mg/dL, and the doctor
report and the FHIR referenceRange.text did the same. The text is still
stored verbatim. The range resolver now takes the reading's sourceUnit (as a
required field, so no reader can forget to select it) and, for a converted
reading, leaves the window's text empty so every surface states the converted
bounds in the marker's unit, and hands the printed text over separately with
its unit. The lab DTO carries it as printedReferenceText, and the note beside
a reading shows it as "as printed in mmol/L: ...".
2026-10-14 19:10:49 +02:00
Marc-André Bombeck 63882bf3ec fix(labs): give the draw date a full-width row
The lab form placed the draw date in the second column of a two-column
grid. DateTimeField sets its date and time halves side by side from sm
up, so the date half was squeezed until a date could only be set
through the calendar. The value and the date now stack in one column,
as in the measurement form, and the date can be typed again.

Refs #1214
2026-10-14 18:58:55 +02:00
BernhardBuckel 747e0964ad feat(labs): show a reading's conversion in the scan review and beside the value
Slice 3 of phase 3 of #1095. The scan review no longer treats every reading in
another unit as unwritable. The server tells it which analyte the matched marker
is (markerAnalyteKey on each extracted row); a row whose unit differs but can be
converted starts selected and carries a badge saying what Save will store and
what the report stated ("Saved as 100.9 mg/dL, converted from 5.6 mmol/L"). A
row that cannot be converted keeps the existing blocked badge and error. Save
still sends what the report printed; the server converts, as in slice 2.

The review's duplicate flag also recognises a re-scan of a reading that was
stored converted, by what the report printed, the same rule the commit applies.

A converted reading carries a quiet "converted from 5.6 mmol/L" on the lab list
(row and tile) and the history list (phone and table), so a number nobody typed
can always be traced back to what the report printed.

Strings in all seven locales.

Refs #1095
2026-10-11 20:41:08 +02:00
BernhardBuckel caa7a937fd feat(labs): convert a reading into its marker's unit when the pair is known
Slice 2 of phase 3 of #1095. A reading that stated a unit other than its
marker's was refused. When the marker's analyte is known and the registry has the
pair, the three write paths now convert it instead: POST /api/labs, the OCR
commit and the document commit.

The converted value is stored at full precision in the marker's unit, with what
the report printed in the existing source_value and source_unit columns. The
report's own reference window is in the printed unit, so it is converted with the
value; otherwise the verdict would compare a converted value with an unconverted
window. A pair the registry does not have is still refused as before (the 422
now says why), as is a marker whose analyte is unknown.

The marker's key is filled the first time a reading needs it. The same scan
committed again is still a duplicate: a converted row holds the number in the
marker's unit, so the duplicate check also matches on what the report printed.
Editing the value of a converted reading clears the conversion record, because
the number is then the person's own.

The lab result DTO and the OpenAPI schemas (labs and the OCR commit) carry
converted, sourceValue and sourceUnit.

Refs #1095
2026-10-11 20:28:00 +02:00
BernhardBuckel 08c69d4a5a test(labs): give the biomarker fixtures the new analyteKey field
BiomarkerDto gained analyteKey, and two component test fixtures typed as it
were missing the field, which the typecheck job rejects.
2026-10-11 20:16:31 +02:00
BernhardBuckel 52ea3b9c2f feat(labs): link a marker to its analyte for the unit conversion
Slice 1 of phase 3 of #1095. A Biomarker row keeps only its name, so nothing
said which analyte it was. This adds the explicit alias list in the catalog the
issue settled on, including the registry-only keys (urea, blood urea nitrogen,
uric acid, total calcium, total bilirubin), and sets biomarkers.analyte_key
(from migration 0385) from it.

matchAnalyteKey equals a marker's folded name against the localised names of the
catalog seeds the registry knows and against the alias list. It matches the
whole name only, so "Calcium (ionisiert)" is not "Calcium"; a name two analytes
claim matches neither; and the marker's own unit must be one the analyte reaches,
so a marker called "Glucose" in a unit the registry cannot convert stays
unlinked.

The key is set when a marker is created (the biomarker route, the mint used by
lab writes, the legacy backfill) and, for an existing marker, by
ensureAnalyteKey the first time a reading needs it. It never overwrites a key
that is set. There is no boot job for the existing markers: the conversion that
uses the key fills it on first use, and a sweep can be added later if wanted.

The key is returned on the biomarker API and in the OpenAPI schema.

Refs #1095
2026-10-11 20:04:43 +02:00
Marc-André Bombeck f363405df0 Merge the settings and admin UI round into release/v1.42.0 2026-10-08 20:21:39 +02:00
Marc-André Bombeck 991764b0c8 Give settings cards one action row at the foot
The TOTP enable, the source-priority reset, the biomarker and record add
actions, and the about-me, profile-facts, emergency and condition saves
move into SettingsCardActions, right-aligned and last in the card. The
emergency Save waits for a change like its neighbours, an empty list
leaves its add action to the empty state, and the source ladder keeps
its up/down buttons side by side on a phone.
2026-10-08 20:20:03 +02:00
Marc-André Bombeck 005cb32ea8 Give every empty list one empty state and one add action
EmptyState now has a single action shape: centred at its own width on
the 44 px tap floor, never stretched edge to edge on some pages and
compact on others; the per-call-site size switch is gone, and the
dashed card takes the card radius. While a list is empty its empty
state carries the add action, so the header drops its own add button
there (measurements, mood, medications, labs, vaccinations, documents,
illness, check-ups, visits, procedures). The dashboard medication tile
of an account without medications offers 'Add a medication' instead of
'no data in the chosen range'.
2026-10-08 18:53:24 +02:00
Marc-André Bombeck 3f00d2effd Merge remote-tracking branch 'origin/release/v1.42.0' into v142/ui-audit 2026-10-08 17:02:21 +02:00
Marc-André Bombeck 03f374794e Settle the form sheets on one anatomy
Field labels no longer lose the space before '(optional)' or set the
colon apart from a unit, and a question label carries no colon after its
question mark. Cancel next to a primary is the outline button in every
form, the illness sheet's selects span the field width, and the reminder
sheet drops a description that repeated the page subtitle. On a phone a
sheet now opens with focus on itself rather than its first field, so a
date or name field no longer raises the keyboard over a sheet nobody has
read yet.
2026-10-08 16:20:42 +02:00
Marc-André Bombeck 8bcb3e6301 fix: keep the two-step on chart points on touch
A point and a calendar cell are small targets; one tap that opened the
day opened days by accident. On a touch screen the first tap shows the
value again and the tooltip's calm 44 px row opens the day, on every
day-linked chart and calendar alike. A date in a list still opens in one
tap; a click on a fine pointer still opens directly. The tooltip keeps
not gliding into place.
2026-10-08 16:04:54 +02:00
Marc-André Bombeck fee6088e08 feat: open the day with one tap and from every place a day is shown
A tap on a point, a bar, a calendar cell or a date now opens the day at
once, as a click does; the tooltip's second step is gone and the tapped
value heads the day. The dashboard's charts (not its today area), the
adherence chart, the rhythm events, the ECG list and detail and the rest
mode notes open their days too.

The day's header carries the close control top left, the Coach panel's
own toggle and glyph, the date on one centred line and the arrows on the
right. While the day is docked, the Coach button and the documents bar
move clear of it.

Smooth the layer: the tooltip no longer glides into place on touch, the
neighbouring day is read before a step, the sheet animates in 300 ms and
not at all under reduced motion, and the opener stays put while the page
beside the docked day reflows.
2026-10-08 15:56:40 +02:00
Marc-André Bombeck 7fbde1bc83 feat: open the day from every chart drawn in days
Move the chart's doors to the day (click, the touch tooltip's button, the
dashed line through the open day, the row of day dots, the caption) into
one hook and give it to every chart with a date axis: recovery, sleep
duration and stages, the mood line and calendar, the intake calendar,
water and caffeine, lab markers, custom metrics, questionnaires and basal
temperature. Heatmaps share one adapter; every chart's keyboard way to a
day is its data table or the dated list beside it.
2026-10-08 15:19:09 +02:00
Marc-André Bombeck bf83d414e2 feat: open any past day as a layer over the page
A date is now a door to its day (#613). `?day=YYYY-MM-DD` opens the day
over whichever page is open: docked beside it from 1280 px, the way the
Coach's conversations panel sits, a sheet from the right below that, and a
bottom sheet on a phone that opens at a little over half the height and
grows to full height from its handle. On /coach it is always a sheet, so
there is never more than one docked panel. Back and Escape close it, the
previous and next day replace the history entry instead of adding one,
Alt with an arrow steps a day, focus moves to the day's heading on open and
returns to whatever opened it on close, and a polite region names the day.
A malformed or future date is dropped from the URL.

The day shows the value it was opened from with its comparison, what ran
through the day, the readings against the person's own usual range on a
short number line (eight curated, the rest behind "All values"), and what
happened in order of the clock, each row linking to its record. Loading,
failure, an empty day and areas a grant does not cover each read as such.
The footer offers the timeline when that module is on and capture for the
day, with the capture forms starting on that date.

Doors into it: a click on a daily point of a metric chart (a tap shows the
value and the tooltip offers the day on touch screens), the dates in the
chart's data table, a quiet row of dots under the axis for days with
entries and a ring for notable ones, the lab chart and lab readings, the
measurement, mood and intake lists, symptom and illness day headings,
episode onset and recovery, document dates, workout dates, the workout
detail, the mood and adherence heatmaps, and the days a Coach answer's
get_day calls read, shown as chips. The next planned visit carries what
happened since the last one, each date opening its day, with a doctor
report for that window.

Not here, and frozen by a guard: the dashboard's today area, mini charts
in tiles, the cycle calendar, model-written text, future dates, the
clinician share link and the doctor-report PDF.
2026-10-08 14:20:01 +02:00
Marc-André Bombeck 29798a76e3 fix(labs): keep the trend column as wide as its sparkline on a wide list
The wide tier let the trend column grow to 8rem while the sparkline it
holds is a fixed 72px glyph, so at 1920 px an empty 56 px strip opened
between the sparkline and the chevron. The column now stays 72px in both
tiers; the extra width goes to the range bar and the name, as before.

The wide-list spec reads the resolved grid tracks and asserts the trend
track is 72px at every width it covers.
2026-10-04 14:28:04 +02:00
BernhardBuckel a1a84f924b feat(labs): let the lab list's range bar use a wide card
On a wide window the compact lab list was one five-column row whose only
flexible column was the name: the name column sat mostly empty while the range
bar and the trend stayed small at the right edge.

The list's card is now a container, and the columns follow its width instead of
the window's. Below 64 rem of card the row is the lg table it was, with the
range bar at 12 rem; from 64 rem the bar column grows from 12 to 18 rem and the
trend column from 72 px to 8 rem, and the bar fills its column. The two tiers
exclude each other, so the result does not depend on the order the CSS is
emitted in. The trend sparkline itself is unchanged.

From lg up a long analyte name wraps instead of being cut off; a phone keeps the
single line with an ellipsis, and the bar keeps its own 12 rem cap there.

The shared 1280 px frame is untouched; a Playwright spec measures it on /labs,
/measurements and /mood at 1280, 1920 and 3440 px.

Fixes #1057
2026-10-04 10:56:43 +02:00