The review stage is a list of readings to compare and correct, but it sat in
the default 448 px dialog, so with several readings it only grew taller.
- ResponsiveSheet gains an opt-in 6xl width tier (72rem). Nothing else
changes width; the Sheet branch on phones ignores the tier as before.
- The review stage uses it. The picking stage stays narrow.
- Each row lays out from the width of its container, not the window:
stacked in a narrow dialog, and once the dialog is wide enough the reading
sits on the left with its fields on the right.
- The field grid (value, unit, date) is a container of its own, so it takes
three columns when the fields have room for them, whatever the window
width. The result-text span follows the same query.
- The dialog-overflow e2e spec covers the review stage at 390, 560, 768,
1280, 1920 and 3440 px. 560 is wider than a phone's field grid needs but
below the window sm breakpoint, which is what tells a container query from
a window one.
Refs #1056
A date-only value is stored at 12:00 UTC. The lab list and history, the
document cards and pickers, the document date suggestion, extracted
fact dates, source-picker rows and the compliance and mood heatmaps
formatted that instant in the reader's zone, which is the next day from
UTC+12 to UTC+14.
`useCalendarDate` formats such a value through the UTC-pinned calendar
formatter the vaccination list already uses, with the same field order
and locale as instant dates. Lab readings hold both kinds, so
`useLabDate` reads a noon-UTC anchor as its calendar date and a reading
typed with its time of day in the reader's zone. A document without a
filing date shows its upload day, an instant, in the reader's zone.
Range bars and the lab list, detail rows, chart tooltip and reference
ranges printed numbers with a plain `String()`, so a German reader saw
"1.8 mIU/L" and "61.3 kg" under a German interface. The same was true
of the mean, GMI, eA1C and the advanced indices on the glucose panel.
`RangeBar` now prints value, bounds and delta through the locale number
formatter and takes an optional `formatValue` for surfaces with their
own precision. Lab values keep their trim rule (whole numbers bare, at
most two decimals) in `formatLabValue`, which now hands the digits to a
caller-supplied locale formatter; `useLabNumber` wires it to the
reader's locale for every lab surface. Inputs are unchanged.
A PDF longer than the pages a scan renders was read from its first ten
pages, and the cut was recorded only in the wide event. The person checking
the extracted rows had no way to know that values on later pages were never
read.
The rasterizer now returns the PDF's page count, the extract response
carries pageCoverage { read, total } when the cap applied, and the review
screen says how many of the pages were read.
The review dialog silently dropped any selected reading that could not be
written (no date, no unit, no value) and saved the rest. When nothing was
left it showed "Select at least one reading to save", which described a
different situation and said nothing about what was missing.
A save is now all-or-nothing over the selected readings. When one is
incomplete, nothing is written; the dialog states how many readings need
attention, marks each missing field (aria-invalid, inline message, red
border, required marker on the label) and moves focus to the first one.
Marks appear after a save attempt and follow the edits. The "nothing
selected" message is kept for that case only.
Validation is a pure function next to the payload mapping, so the rule that
blocks a save and the rule that builds the payload cannot drift apart.
Adds EN and DE strings; the other locales are left to the maintainers.
Refs #1055
Reading a document, scanning a lab report and turning a medication
description into a schedule follow documentAi, labsOcr and
medicationExtract. Unavailable, the action is not offered. With only the
document-reading consent missing, the place that reads asks for it and
grants exactly that (ai_extraction), nothing wider.
Refusals are read by meta.errorCode: a 403 is no longer always called a
missing consent, and a spent daily budget no longer shows the rate-limit
sentence.
The reset after "Save and add another" cleared the biomarker and passed
the picker `undefined`, which switched it to its own internal state. It
went on showing the marker it last held while the form value was empty,
so the next save refused with "Pick a biomarker first" under a visibly
picked marker, and a later pick could land on the first catalogue entry.
The picker is always controlled now (an empty pick shows the
placeholder), and "Save and add another" keeps the marker, the draw date
and the visit, clearing only the reading, its note and its printed
range. Focus moves to the value field for the next entry.
useRecordCapabilities answers per section now. canWriteDomain and
canManageDomain read the two lists the account payload publishes; in
one's own record they are always true, and under a refused, pending or
unproven context always false. canManage becomes the coarse switch,
true when any section is manageable, and is what the banner and the
navigation read.
Every add, edit and delete control names its own section: labs, mind,
profile, illness, cycle, medications, measurements, documents. Creates
that a WRITE route answers (visits, practitioners) ask canWriteDomain.
The generic delete button, the selection bar, the capture picker, the
dashboard quick entry and the bottom nav take the section from their
callers. Controls whose routes resolve the caller rather than the
record (settings shortcuts, chart overlay preferences, custom metrics,
the Today rail, OCR, efficacy targets, credential tabs) ask for the
caller's own record instead, and the customise-shortcut guard now
requires that shape.
The vault has no delegated write route, so its controls stay withheld
under every grant, and the documents page says so in one sentence
where the upload control would be, in all seven locales.
A floor at or above its ceiling fell through to the one-sided branch and
was read as "minimum only", which paints a high reading green. That is
the wrong direction for a transcription error to fail in: the colour
answers a question nobody could answer from that data.
Each one-sided branch now requires the OTHER bound to be absent, so a
present-but-impossible pair lands on the neutral dot instead. It matches
lab-reference-range-bar.tsx, which renders nothing for the same input —
the two components sitting next to each other should not disagree about
what a nonsense range means.
The file had no test. It has one now, covering all five window shapes
plus the zero-width band; with the two conditions relaxed again, exactly
the two new cases fail and the four existing ones stay green.
A lab runs its own method on its own device, so the window a physician
evaluates a value against is the one printed next to it on that report,
not a catalog band averaged over every lab. Reading a report pulled the
value and dropped that range: the extraction asked for it, the commit
handed it to the biomarker resolver, and the resolver only uses it when
it mints a NEW marker. For every analyte the user already had — the
normal case after a first panel — the printed range was read and then
thrown away.
Add `sourceReferenceLow` / `sourceReferenceHigh` / `sourceReferenceText`
to `LabResult` and carry the range from the report to the reading. The
text is stored whether or not numbers can be read out of it, because
"bis 5,0" and "negativ" state a window too; a range that could not be
parsed is kept verbatim, never replaced with invented bounds.
`resolveEffectiveReferenceRange` is the one place the precedence lives:
the source window wins for that single reading, and the catalog stays
the net for readings without one. A printed string with no derivable
bound does not displace the catalog. Every surface that judges a
reading routes through it — the API verdict, the doctor report, the
insights blocks and per-marker assessment, the coach snapshot, the MCP
read and the FHIR `referenceRange` — so a value cannot read in range on
one surface and out on another.
The API keeps `referenceLow` / `referenceHigh` as the window in force,
so a client that reads only those two renders the right range and the
right verdict with no change of its own; the catalog band, the source
window, its origin and a divergence flag ride alongside for clients
that want to show both.
Read side: the chart draws the source window as a second, visually
distinct band with the reading it came from named beneath it, the
reading rows name the printed range and the catalog band where the two
disagree, and the doctor-report PDF prints the report's own string with
a footnote naming the saved range. Entry side: one optional field on
the lab form, folded away until asked for, and the printed range is
editable on the scan review screen.
The range parser covers the notations German and English reports
actually print — two-sided, one-sided, comma or dot decimals, thousands
separators, trailing units — reads units without ever converting them,
and refuses to guess on anything ambiguous.
Resolve the catalog slug from both the current-locale display name and the
English canonical name. A marker stores the catalog name as it read at
creation time, so one minted under the English default and then viewed in
another locale never matched a map built only from the current locale's
names — its rich per-biomarker description silently fell back to the generic
line. The English bundle is always in the client chunk, so adding its names
makes the lookup independent of the locale the marker was created in.
Tidy the header control cluster:
- Drop the standalone "adjust target range" control and its sheet; the
reference bounds are already editable inside the full marker editor behind
the pencil. Remove the now-dead handler, mutation, and `targetRange.*`
strings across all locales.
- Give the show-all-values, edit, and delete controls one shared ghost-icon
treatment instead of the show-all control's separate muted variant.
- Add hover tooltips to edit and delete, matching the other icon controls.
- Order the controls left → right: delete, edit, show all values, add value.
The detail page fetched a single limit=500 window and sorted client-side,
silently truncating any marker that crossed 500 readings. Switch to an
offset-paginated useInfiniteQuery: it loads a page at a time, a 'Load more'
control reveals the rest, and the chart and stat strip render the
accumulated set so loading more extends the trend.
Add coverage for the new biomarker-assessment seam and the marker detail
surface:
- the generator serves today's cache, re-stamps unchanged readings without an
LLM call, and regenerates only when the latest-reading fingerprint changes
- the read-only endpoint returns the envelope, 422s a missing id, and honours
the auth + insightStatus gates
- the detail page paints the stat strip, the chart placeholder, and the
assessment card
- the biomarker resource route drops the marker with its readings in one
userId-narrowed transaction and rejects an inverted target range
Hold the input gate independent of the worker's forced run so an idle marker
re-stamps cached text instead of regenerating, and list the new route on the
non-Coach gate allowlist.
Add first-class qualitative lab findings (positive / negative / borderline
serology) alongside the existing numeric path. A LabResult is now EITHER a
numeric reading (value + unit, optional reference bounds) OR a qualitative one
(valueText, e.g. "negativ"), never both, never neither.
- schema: make `value` nullable, add `value_text`; migration 0181 is additive
(DROP NOT NULL + ADD COLUMN), every existing numeric row is untouched.
- validation: numeric-XOR-qualitative refine on create + update; unit/bounds
apply to the numeric path only; valueText capped at 120 chars. The single
resource PUT rejects a cross-type edit.
- serialise: carry valueText through both DTOs; a qualitative row reports the
neutral `unknown` range verdict (no number to classify).
- FHIR: a qualitative result emits valueCodeableConcept — SNOMED qualifier
value for confidently-known terms (Negative 260385009, Positive 10828004,
Not detected 260415000, Detected 260373001), text-only for borderline /
grenzwertig and any unrecognised term. The raw text always rides .text.
- UI: a numeric/qualitative toggle in the lab form; list, history, detail,
chart, sparkline, and the doctor-report PDF all render qualitative readings
as their text and never plot or divide on a null value.
- i18n: new labs.form keys across all six locales.
- openapi: response carries a nullable value + valueText; regenerated.
The lab list shipped a second bespoke compact-tile shape and a
centred Loader2 that disagreed in size with the page spinner above it.
- Lab cards now title themselves with CardHeader/CardTitle and pin the
sparkline + delete control in CardAction, matching the canonical card
contract; the py-4 content override is dropped so the card token
drives spacing.
- Loading paints a tile-shaped Skeleton stack via the shared primitive
instead of the bespoke spinner, removing the size drift and the
layout pop-in.