fix(labs): keep the biomarker chart axis at zero for a range starting at zero
A reference window of 0-130 padded the axis to -13, a tick that reads like a value for a concentration that cannot be negative. The pad only goes below zero when the data already does.
This commit is contained in:
1 parent
4a13004917
commit
24e6972f95
1 file changed
+4
-1
@@ -163,7 +163,10 @@ export function LabBiomarkerChart({
|
||||
const min = Math.min(...candidates);
|
||||
const max = Math.max(...candidates);
|
||||
const pad = (max - min || Math.abs(max) || 1) * 0.1;
|
||||
return [min - pad, max + pad];
|
||||
// A reference window that starts at 0 (LDL "0–130") must not drag the
|
||||
// axis below zero: a concentration cannot be negative, and a "-13" tick
|
||||
// reads as a value. The pad only stays below zero when the data already is.
|
||||
return [min >= 0 ? Math.max(0, min - pad) : min - pad, max + pad];
|
||||
}, [points, lowerBound, upperBound, sourceBand]);
|
||||
|
||||