Range bars and the lab list, detail rows, chart tooltip and reference ranges printed numbers with a plain `String()`, so a German reader saw "1.8 mIU/L" and "61.3 kg" under a German interface. The same was true of the mean, GMI, eA1C and the advanced indices on the glucose panel. `RangeBar` now prints value, bounds and delta through the locale number formatter and takes an optional `formatValue` for surfaces with their own precision. Lab values keep their trim rule (whole numbers bare, at most two decimals) in `formatLabValue`, which now hands the digits to a caller-supplied locale formatter; `useLabNumber` wires it to the reader's locale for every lab surface. Inputs are unchanged.
61 lines
2.0 KiB
TypeScript
61 lines
2.0 KiB
TypeScript
import { describe, expect, it } from "vitest";
|
||
import { renderToStaticMarkup } from "react-dom/server";
|
||
|
||
import { I18nProvider } from "@/lib/i18n/context";
|
||
|
||
import { LabReferenceRangeBar } from "../lab-reference-range-bar";
|
||
|
||
function render(
|
||
props: Partial<React.ComponentProps<typeof LabReferenceRangeBar>> = {},
|
||
locale: "en" | "de" = "en",
|
||
) {
|
||
return renderToStaticMarkup(
|
||
<I18nProvider initialLocale={locale}>
|
||
<LabReferenceRangeBar
|
||
value={72}
|
||
referenceLow={60}
|
||
referenceHigh={100}
|
||
unit="bpm"
|
||
{...props}
|
||
/>
|
||
</I18nProvider>,
|
||
);
|
||
}
|
||
|
||
describe("<LabReferenceRangeBar>", () => {
|
||
it("renders the existing colored range bar for a complete numeric range", () => {
|
||
const html = render();
|
||
|
||
expect(html).toContain('data-slot="lab-reference-range-bar"');
|
||
expect(html).toContain('data-slot="target-range-bar"');
|
||
expect(html).toContain("bg-info/35");
|
||
expect(html).toContain("bg-warning/35");
|
||
expect(html).toContain("bg-success/35");
|
||
expect(html).toContain("left:0%;width:");
|
||
});
|
||
|
||
it.each([
|
||
["a qualitative value", { value: null }],
|
||
["a missing reference range", { referenceLow: null, referenceHigh: null }],
|
||
["an inverted range", { referenceLow: 100, referenceHigh: 60 }],
|
||
])("omits the bar for %s", (_label, props) => {
|
||
expect(render(props)).not.toContain('data-slot="lab-reference-range-bar"');
|
||
});
|
||
|
||
it("renders one-sided upper and lower reference limits", () => {
|
||
expect(render({ referenceLow: null })).toContain('aria-label="≤100 bpm"');
|
||
expect(render({ referenceHigh: null })).toContain('aria-label="≥60 bpm"');
|
||
});
|
||
|
||
it("prints the reading and its range in the reader's number format", () => {
|
||
const html = render(
|
||
{ value: 1.8333, referenceLow: 0.4, referenceHigh: 4.05, unit: "mIU/L" },
|
||
"de",
|
||
);
|
||
expect(html).toContain('aria-label="0,4–4,05 mIU/L"');
|
||
// Lab precision: at most two decimals, then the locale's separator.
|
||
expect(html).toContain("1,83 mIU/L");
|
||
expect(html).not.toMatch(/\d\.\d+ mIU\/L/);
|
||
});
|
||
});
|