Files
HealthLog/src/lib/openapi
Marc-André Bombeck a1dbd9c831 fix(medications): apply the post-opening clock only where a container has one
A supply container went EXPIRED 30 days after its first use no matter what
kind of container it was. That window exists because puncturing an injection
pen exposes its contents and the product information caps how long the rest
stays usable; a blister of tablets has no such limit, every tablet sits in
its own sealed cavity, and pressing the first one out says nothing about the
rest. The state machine never read `containerType`, so a tablet pack opened
five weeks ago had its remaining stock written off.

The clock now keys off the container kind. PEN and AMPOULE carry it: both are
a single sealed reservoir that the first dose breaches. BLISTER, INHALER,
BOTTLE and OTHER do not: their units stay individually sealed, or the
arrangement is simply unknown, and a fixed 30 days would be a number nobody
entered. The printed expiry still applies to every kind, so an unknown
container is not an unbounded one.

`computeExpiresAt` takes the kind too, so a clock-less container with no
printed date now persists no `expiresAt` at all and the daily expire scan
never sees it.

The per-item PATCH gains a way back out: `markAsFirstUseAt` accepts null and
clears the opening date, which is the correction a container needs after the
intake hook auto-opened it from a back-dated dose.

Also drops `daysRemainingInUse`. It had no caller anywhere in the tree and
its docblock described a chip that does not exist.
2026-07-26 18:00:07 +02:00
..