Slice 2 of phase 3 of #1095. A reading that stated a unit other than its marker's was refused. When the marker's analyte is known and the registry has the pair, the three write paths now convert it instead: POST /api/labs, the OCR commit and the document commit. The converted value is stored at full precision in the marker's unit, with what the report printed in the existing source_value and source_unit columns. The report's own reference window is in the printed unit, so it is converted with the value; otherwise the verdict would compare a converted value with an unconverted window. A pair the registry does not have is still refused as before (the 422 now says why), as is a marker whose analyte is unknown. The marker's key is filled the first time a reading needs it. The same scan committed again is still a duplicate: a converted row holds the number in the marker's unit, so the duplicate check also matches on what the report printed. Editing the value of a converted reading clears the conversion record, because the number is then the person's own. The lab result DTO and the OpenAPI schemas (labs and the OCR commit) carry converted, sourceValue and sourceUnit. Refs #1095