Files
HealthLog/tests
Marc-André Bombeck c7b3f6e4d0 fix(labs): drop a unitless text range when a marker adopts a real unit
A marker minted from a text result that stated no unit kept the printed
numbers as its range, and the first numeric reading then gave the marker
its unit without touching them, so a "30 - 100" printed in ng/mL became a
window in nmol/L. Numbers stated without a unit are dimensionless: they
stay when the adopted unit is the unity "1" and otherwise give way to the
window the first number printed in its own unit, or to none.