The hypertensive-crisis floors were defined in three modules with a
divergent diastolic value: the notification engine and the Coach acute
clause used 180/120, but the dashboard hero used 180/110. A reading like
170/112 lit the red critical-BP banner on the hero yet never tripped the
notification alarm or matched the Coach's stated acute number — one
surface said crisis, the other two stayed calm on the same row.
Promote the absolute floors into a dependency-free clinical-floors leaf
and have the hero, the safety-floor engine, the status registry's fever
band, and the illness escalation all import from it. The crisis diastolic
floor is the guideline-correct 120 (ACC/AHA hypertensive urgency); the
wider 110 hero net is dropped so the surfaces tell one story. A coverage
test pins that every consumer resolves the same constants.