Marc-André Bombeck 55c029daae fix(pulse): score resting heart rate, exclude workout samples from target
Every surface that applied a resting-pulse target judged the raw PULSE
series against a resting band. Apple Health maps all heart-rate samples
— including workout HR — onto PULSE, and the resting figure onto a
separate RESTING_HEART_RATE type. A single workout emits hundreds of
expected-high samples, so the resting-target evaluation read a large
share "outside target" and tanked the in-target % / consistency even
when the clean resting series averaged a healthy figure.

Judge the resting band against a resting series. A shared helper prefers
RESTING_HEART_RATE; when the user has none it derives a proxy from the
low percentile of each day's PULSE samples, so a dense workout burst
sitting in the upper tail cannot drag the resting estimate up. Applied
to the resting-pulse tile + its consistency strip, the pulse in-target %
in the assessment snapshot, and the dashboard / sub-page classification.
Raw heart rate, where it is merely charted, no longer carries the
resting-band overlay. The doctor report is unchanged — it reports raw
heart-rate stats factually, with no resting-target judgment to mislead.