A converted reading's bounds move with its value, but the printed range text stays in the unit the report used, and every reader preferred that text: the list showed "Report range 3.9 to 5.5" beside 100.9 mg/dL, and the doctor report and the FHIR referenceRange.text did the same. The text is still stored verbatim. The range resolver now takes the reading's sourceUnit (as a required field, so no reader can forget to select it) and, for a converted reading, leaves the window's text empty so every surface states the converted bounds in the marker's unit, and hands the printed text over separately with its unit. The lab DTO carries it as printedReferenceText, and the note beside a reading shows it as "as printed in mmol/L: ...".