Marc-André Bombeck 9e47b47b00 fix: honour the chosen glucose unit in the measurements list
The list renders a reading through the metric/imperial transform registry,
and glucose is not in it, so the list kept saying 95 mg/dL while the
dashboard tile said 5.3 mmol/L for the same reading — correct on both
counts and disagreeing anyway.

The edit sheet is the half that could have done damage. Its label follows
the same resolution as the row, so on mmol/L the number in the input is in
mmol/L and has to come back the other way before the PATCH. Row, edit seed
and inversion move together; converting the display alone would rewrite a
95 mg/dL reading as 5.3 the first time somebody corrected a typo.

An mg/dL account edits in the unit the column already holds and stays on
the identity path, deliberately: the converter rounds, and sending an
mg/dL edit through it would quantise a stored 95.48 the moment somebody
opened the sheet to fix a note. A row whose stored unit is not the type's
canonical one still shows verbatim, as before.
2026-09-03 06:05:58 +02:00
..