Marc-André Bombeck fd2bd67ff3 feat(labs): keep the reference range a report prints beside a value
A lab runs its own method on its own device, so the window a physician
evaluates a value against is the one printed next to it on that report,
not a catalog band averaged over every lab. Reading a report pulled the
value and dropped that range: the extraction asked for it, the commit
handed it to the biomarker resolver, and the resolver only uses it when
it mints a NEW marker. For every analyte the user already had — the
normal case after a first panel — the printed range was read and then
thrown away.

Add `sourceReferenceLow` / `sourceReferenceHigh` / `sourceReferenceText`
to `LabResult` and carry the range from the report to the reading. The
text is stored whether or not numbers can be read out of it, because
"bis 5,0" and "negativ" state a window too; a range that could not be
parsed is kept verbatim, never replaced with invented bounds.

`resolveEffectiveReferenceRange` is the one place the precedence lives:
the source window wins for that single reading, and the catalog stays
the net for readings without one. A printed string with no derivable
bound does not displace the catalog. Every surface that judges a
reading routes through it — the API verdict, the doctor report, the
insights blocks and per-marker assessment, the coach snapshot, the MCP
read and the FHIR `referenceRange` — so a value cannot read in range on
one surface and out on another.

The API keeps `referenceLow` / `referenceHigh` as the window in force,
so a client that reads only those two renders the right range and the
right verdict with no change of its own; the catalog band, the source
window, its origin and a divergence flag ride alongside for clients
that want to show both.

Read side: the chart draws the source window as a second, visually
distinct band with the reading it came from named beneath it, the
reading rows name the printed range and the catalog band where the two
disagree, and the doctor-report PDF prints the report's own string with
a footnote naming the saved range. Entry side: one optional field on
the lab form, folded away until asked for, and the printed range is
editable on the scan review screen.

The range parser covers the notations German and English reports
actually print — two-sided, one-sided, comma or dot decimals, thousands
separators, trailing units — reads units without ever converting them,
and refuses to guess on anything ambiguous.
2026-08-07 21:40:41 +02:00

290 lines
11 KiB
TypeScript

"use client";
/**
* v1.18.9 — a single proposed Lab-OCR row on the review screen.
*
* Mandatory human review: each row is shown for per-row confirm/edit/discard.
* The checkbox confirms; the inline fields edit analyte / value-or-valueText /
* unit / reference range / date. Server-computed hints surface as calm badges:
* a new-vs-existing-biomarker hint, a duplicate warning (the row defaults to
* unchecked when flagged), and a low-confidence flag per the model's self-score.
*
* The no-alarming-colour ethos holds: an out-of-range or duplicate row is not
* painted red — these are informative `secondary`/`outline` badges, same weight
* as the in-range state.
*/
import { useId } from "react";
import {
AlertCircle,
FilePlus2,
Link2,
Ruler,
TriangleAlert,
} from "lucide-react";
import { Badge } from "@/components/ui/badge";
import { Checkbox } from "@/components/ui/checkbox";
import { DateField } from "@/components/ui/date-field";
import { Input } from "@/components/ui/input";
import { Label } from "@/components/ui/label";
import { useTranslations } from "@/lib/i18n/context";
import type { OcrReviewRow } from "./ocr-review-types";
/** Below this per-field confidence the field is flagged for a second look. */
const CONFIDENCE_THRESHOLD = 0.6;
export function OcrRowEditor({
row,
onChange,
}: {
row: OcrReviewRow;
onChange: (next: OcrReviewRow) => void;
}) {
const { t } = useTranslations();
const fieldId = useId();
const isQualitative = row.valueText !== null && row.valueText !== undefined;
const lowValueConfidence =
!isQualitative && row.confidence.value < CONFIDENCE_THRESHOLD;
const valueUnreadable = !isQualitative && row.value === null;
// The model self-scores each field it transcribed. Surface a single calm
// per-row flag when ANY tracked field came back below the threshold so a
// shaky read is visible at a glance — including on qualitative rows, which
// have no value-confidence footnote of their own. Informative, not alarming.
const lowRowConfidence =
row.confidence.analyte < CONFIDENCE_THRESHOLD ||
row.confidence.unit < CONFIDENCE_THRESHOLD ||
(isQualitative
? row.confidence.value < CONFIDENCE_THRESHOLD
: lowValueConfidence);
// v1.18.10 (#5) — a NEW numeric biomarker mints its catalog reference range
// from THIS extracted row. The range is therefore load-bearing and worth a
// second look. Surface the range confidence prominently for new numeric
// markers, and call it out explicitly when the model was unsure (or set no
// bounds at all) so the user verifies the range it will be judged against.
const isNewNumericMarker = !isQualitative && row.biomarkerMatch === "new";
const lowRangeConfidence = row.confidence.range < CONFIDENCE_THRESHOLD;
const hasBounds = row.referenceLow !== null || row.referenceHigh !== null;
const flagRange = isNewNumericMarker && (lowRangeConfidence || !hasBounds);
return (
<div className="space-y-3 rounded-lg border p-3">
<div className="flex items-start gap-3">
{/* The checkbox is the PRIMARY per-row confirm on a touch-first OCR
review screen, so it needs a ≥44px hit area on coarse pointers. The
wrapping label supplies the touch target (and forwards the click to
the control) without enlarging the 20px glyph or bloating the row on
desktop, where the negative margins collapse the padding back. */}
<label
htmlFor={`${fieldId}-confirm`}
className="-m-3 flex min-h-11 min-w-11 cursor-pointer items-start justify-center p-3 sm:m-0 sm:min-h-0 sm:min-w-0 sm:p-0"
>
<Checkbox
id={`${fieldId}-confirm`}
checked={row.confirmed}
onCheckedChange={(checked) =>
onChange({ ...row, confirmed: checked === true })
}
className="mt-0.5 min-h-5 min-w-5 sm:mt-1"
aria-label={t("labs.ocr.confirmRow")}
/>
</label>
<div className="min-w-0 flex-1 space-y-1">
<Input
value={row.analyte}
onChange={(e) => onChange({ ...row, analyte: e.target.value })}
aria-label={t("labs.ocr.analyteLabel")}
className="font-medium"
/>
<div className="flex flex-wrap items-center gap-1.5">
{row.biomarkerMatch === "existing" ? (
<Badge variant="outline" className="text-muted-foreground">
<Link2 aria-hidden />
{t("labs.ocr.linksExisting", { name: row.analyte })}
</Badge>
) : (
<Badge variant="outline" className="text-muted-foreground">
<FilePlus2 aria-hidden />
{t("labs.ocr.newBiomarker")}
</Badge>
)}
{row.duplicateOf ? (
<Badge variant="secondary">
<TriangleAlert aria-hidden />
{t("labs.ocr.duplicateWarning")}
</Badge>
) : null}
{lowRowConfidence ? (
<Badge variant="secondary" className="text-muted-foreground">
<AlertCircle aria-hidden />
{t("labs.ocr.lowConfidenceBadge")}
</Badge>
) : null}
</div>
</div>
</div>
<div className="grid grid-cols-2 gap-2 sm:grid-cols-3">
{isQualitative ? (
<div className="col-span-2 space-y-1 sm:col-span-3">
<Label htmlFor={`${fieldId}-vt`} className="text-xs">
{t("labs.ocr.resultLabel")}
</Label>
<Input
id={`${fieldId}-vt`}
value={row.valueText ?? ""}
onChange={(e) => onChange({ ...row, valueText: e.target.value })}
/>
</div>
) : (
<>
<div className="space-y-1">
<Label htmlFor={`${fieldId}-val`} className="text-xs">
{t("labs.ocr.valueLabel")}
</Label>
<Input
id={`${fieldId}-val`}
inputMode="decimal"
value={row.value === null ? "" : String(row.value)}
onChange={(e) => {
const raw = e.target.value.trim();
const parsed = raw === "" ? null : Number(raw);
onChange({
...row,
value:
parsed !== null && Number.isFinite(parsed)
? parsed
: null,
});
}}
/>
</div>
<div className="space-y-1">
<Label htmlFor={`${fieldId}-unit`} className="text-xs">
{t("labs.ocr.unitLabel")}
</Label>
<Input
id={`${fieldId}-unit`}
value={row.unit ?? ""}
onChange={(e) => onChange({ ...row, unit: e.target.value })}
/>
</div>
</>
)}
<div className="space-y-1">
<Label htmlFor={`${fieldId}-date`} className="text-xs">
{t("labs.ocr.dateLabel")}
</Label>
<DateField
id={`${fieldId}-date`}
value={row.takenAt ?? ""}
onChange={(value) => onChange({ ...row, takenAt: value || null })}
/>
</div>
</div>
{/* v1.18.10 (#5) — for a NEW numeric biomarker the reference range below
becomes the marker's catalog range. Make that consequence visible, and
flag low range-confidence / a missing range so the user verifies it
before saving. A calm `secondary` badge, not an alarm. */}
{isNewNumericMarker ? (
<div className="flex flex-wrap items-center gap-1.5">
<Badge variant={flagRange ? "secondary" : "outline"}>
<Ruler aria-hidden />
{flagRange
? t("labs.ocr.rangeVerify")
: t("labs.ocr.rangeFromScan")}
</Badge>
</div>
) : null}
{!isQualitative ? (
<div className="grid grid-cols-2 gap-2">
<div className="space-y-1">
<Label htmlFor={`${fieldId}-lo`} className="text-xs">
{t("labs.ocr.refLowLabel")}
</Label>
<Input
id={`${fieldId}-lo`}
inputMode="decimal"
value={row.referenceLow === null ? "" : String(row.referenceLow)}
onChange={(e) => {
const raw = e.target.value.trim();
const parsed = raw === "" ? null : Number(raw);
onChange({
...row,
referenceLow:
parsed !== null && Number.isFinite(parsed) ? parsed : null,
});
}}
/>
</div>
<div className="space-y-1">
<Label htmlFor={`${fieldId}-hi`} className="text-xs">
{t("labs.ocr.refHighLabel")}
</Label>
<Input
id={`${fieldId}-hi`}
inputMode="decimal"
value={
row.referenceHigh === null ? "" : String(row.referenceHigh)
}
onChange={(e) => {
const raw = e.target.value.trim();
const parsed = raw === "" ? null : Number(raw);
onChange({
...row,
referenceHigh:
parsed !== null && Number.isFinite(parsed) ? parsed : null,
});
}}
/>
</div>
</div>
) : null}
{/* The window as the report printed it. Editable, because the human is
reviewing a transcription: the two bounds above are the derived
reading of this string, and correcting the string is how a range the
parser could not read ("bis 5,0", "negativ") still reaches the row
instead of being dropped. */}
{!isQualitative ? (
<div className="space-y-1">
<Label htmlFor={`${fieldId}-refText`} className="text-xs">
{t("labs.ocr.refTextLabel")}
</Label>
<Input
id={`${fieldId}-refText`}
value={row.referenceText ?? ""}
placeholder={t("labs.ocr.refTextPlaceholder")}
maxLength={120}
onChange={(e) => {
const raw = e.target.value;
onChange({
...row,
referenceText: raw.trim() === "" ? null : raw,
});
}}
/>
</div>
) : null}
{valueUnreadable ? (
<p className="text-muted-foreground flex items-center gap-1.5 text-xs">
<AlertCircle aria-hidden className="h-3.5 w-3.5" />
{t("labs.ocr.valueUnreadable")}
</p>
) : lowValueConfidence ? (
<p className="text-muted-foreground flex items-center gap-1.5 text-xs">
<AlertCircle aria-hidden className="h-3.5 w-3.5" />
{t("labs.ocr.lowConfidence")}
</p>
) : null}
</div>
);
}