Marc-André Bombeck 0849d59ecf test(cycle): pin the fixture clock to the suite's clock
Two cycle suites compute their relative day keys with local Date arithmetic
under TZ=UTC while the routes resolve today in the user's zone, falling back
to Europe/Berlin when the fixture sets none. For two hours every evening the
two clocks disagree about the date and every day-of-cycle assertion is off
by one — the suite was red from 22:00 UTC to midnight and green the rest of
the day. The fixtures now carry an explicit UTC timezone so the test's clock
and the route's clock are the same clock at any hour. Reproduced red at
23:07 UTC, green with the pin at 23:19 UTC.