Commit Graph
5 Commits
Author SHA1 Message Date
Marc-André Bombeck 0ee7e156d3 fix(report): print lab values with the precision they were recorded at
The doctor report PDF printed lab values and reference ranges with one
decimal and the share page with two at most, so a PSA of 0.034 read 0.0
or 0.03 and a TSH window of 0.27 read 0.3, while the labs page kept more.
The labs page itself cut values above 1 to two decimals.

One rule now decides every recorded number (src/lib/format/recorded-number):
a stored value keeps every digit it holds, minus binary float noise, and a
value converted from the unit its report printed keeps the precision of the
printed figure. The report payload carries sourceValue for that. The labs
page, its chart and history, the PDF lab table and footnote, the share
page, the day view and the OCR review all print through it, reference
bounds included. Doses on the PDF and the share page follow the same rule.

Measurement statistics in the PDF and on the share page now share one
per-row precision: up to three significant digits but never more decimals
than recorded, so a waist-to-height ratio of 0.52 no longer reads 0.5;
glucose keeps its unit's precision.

Refs #1228
2026-10-16 11:00:27 +02:00
Marc-André Bombeck 38ef4c7fa7 fix(labs): keep three significant digits for a lab value below one 2026-10-14 19:57:34 +02:00
Marc-André Bombeck fe13fa966b fix(labs): print range bars and lab values in the reader's number format
Range bars and the lab list, detail rows, chart tooltip and reference
ranges printed numbers with a plain `String()`, so a German reader saw
"1.8 mIU/L" and "61.3 kg" under a German interface. The same was true
of the mean, GMI, eA1C and the advanced indices on the glucose panel.

`RangeBar` now prints value, bounds and delta through the locale number
formatter and takes an optional `formatValue` for surfaces with their
own precision. Lab values keep their trim rule (whole numbers bare, at
most two decimals) in `formatLabValue`, which now hands the digits to a
caller-supplied locale formatter; `useLabNumber` wires it to the
reader's locale for every lab surface. Inputs are unchanged.
2026-10-01 22:09:30 +02:00
Marc-André Bombeck a5b3715a46 feat(labs): record qualitative lab results
Add first-class qualitative lab findings (positive / negative / borderline
serology) alongside the existing numeric path. A LabResult is now EITHER a
numeric reading (value + unit, optional reference bounds) OR a qualitative one
(valueText, e.g. "negativ"), never both, never neither.

- schema: make `value` nullable, add `value_text`; migration 0181 is additive
  (DROP NOT NULL + ADD COLUMN), every existing numeric row is untouched.
- validation: numeric-XOR-qualitative refine on create + update; unit/bounds
  apply to the numeric path only; valueText capped at 120 chars. The single
  resource PUT rejects a cross-type edit.
- serialise: carry valueText through both DTOs; a qualitative row reports the
  neutral `unknown` range verdict (no number to classify).
- FHIR: a qualitative result emits valueCodeableConcept — SNOMED qualifier
  value for confidently-known terms (Negative 260385009, Positive 10828004,
  Not detected 260415000, Detected 260373001), text-only for borderline /
  grenzwertig and any unrecognised term. The raw text always rides .text.
- UI: a numeric/qualitative toggle in the lab form; list, history, detail,
  chart, sparkline, and the doctor-report PDF all render qualitative readings
  as their text and never plot or divide on a null value.
- i18n: new labs.form keys across all six locales.
- openapi: response carries a nullable value + valueText; regenerated.
2026-06-20 11:17:43 +02:00
Marc-André Bombeck e9037a0d92 feat(labs): biomarker catalog with server-resolved reference ranges
Add a user-scoped Biomarker catalog so a marker is defined once — name,
unit, lower/upper bound, optional encrypted context, panel — and every
later reading just links it. New /api/biomarkers CRUD plus a structured
/api/labs create path: a biomarkerId resolves the unit + reference range
server-side, so the list and detail DTOs carry the resolved values and
the client never recomputes the range. Lab reads include the linked
marker and fall back to the legacy free-text fields for unlinked rows.

Add a lab-result restore endpoint for the delete-Undo affordance, a
shared serialiser, a static common-panel seed list, and tests for
catalog validation, structured-entry resolution, and the context codec.
2026-06-16 21:05:51 +02:00