A numeric lab reading was stored with its value as received and the marker's
unit stamped on it, so 5.6 mmol/L against a marker kept in mg/dL became
5.6 mg/dL and read as far below range. Both the manual/API write and the
scan commit did this; nothing compared the two units.
- POST /api/labs returns 422 labs.unit.mismatch, with the marker's unit and
the reading's unit in meta, and writes nothing. The unit is compared only
when one was sent: on the biomarkerId path it may be omitted, and the
marker's unit is then the stated one. A qualitative reading has no unit.
- The scan commit skips such a row with reason unit_mismatch, so the outcome
reads partial or failed instead of a clean save, and the toast names the
analytes concerned rather than saying "duplicates".
- The extract response carries the matched marker's unit. The review screen
shows a calm badge on a row in another unit, starts it unticked like a
duplicate, and treats it as a blocking error on the unit field if it is
ticked anyway.
- A small lab-specific normaliser forgives spelling only: spacing, the micro
prefix, the case of the litre, and a unit printed in capitals for a short
list where capitals cannot mean another unit. Case is otherwise significant,
so mIU/L and MIU/L, or g/L and G/L, are never merged.
The document-commit path already refuses a mismatch and is left as it is.
Readings stored wrongly before this cannot be identified, because the
original unit was never kept; they are not touched.
Adds EN and DE strings; the other locales are left to the maintainers. The
OpenAPI spec and the error-code catalogue carry the new code.
Fixes#1094