The reference grounding printed the fasting glucose bands in mg/dL and
the body-temperature band in °C, and the system prompt described time
in range as 70-180 mg/dL. For a reader on mmol/L or Fahrenheit the
model was handed one quantity in two units: the glucose block in
mmol/L, the band beside it in mg/dL.
The grounding block now takes both unit preferences and prints the
general, the diabetes goal and the temperature band in them, while the
placement is still classified on the canonical value. The glucose
block carries the time-in-range band in its own unit, and the prompt
points the model at it instead of naming a unit.
Refs #1067
One-shot prettier pass so the new format:check gate starts from a clean
baseline. Formatting only — no behaviour change. Generator-owned and
vendored artifacts stay untouched via .prettierignore.
The reference-range classifier assumed bands[0] was always the
normal/target band, so any metric whose first band is abnormal was
placed wrong: a healthy BMI 22 read as just outside the reference and
an underweight BMI 17 read as inside; pulse pressure had the same flaw
(Narrow is its first band). The same classifier drives the in-app
four-state explainer, so both surfaces were affected.
Mark the population-normal band explicitly with a `normal: true` flag
on every metric, add `normalBandIndex`, and place values by distance
from the marked band rather than from index 0. `headlineBandText` now
renders the marked band, so BMI grounds against 18.5-24.9 kg/m2.
Exclude daily steps from the Coach grounding: it is fed the intra-day
mean of the step rows, which averages a multi-row day down and can
misplace it below the 8,000 floor. Grounding it on a per-day sum is the
correct fix and is left as a follow-up; until then drop the line rather
than ship a wrong placement.
Extend the classifier and grounding tests for BMI 17/22/27, a pulse
pressure case, the normal-band-not-at-index-0 contract, and that steps
is not grounded.
Surface the population reference bands behind the metrics a Coach turn
carries as a compact, citation-aware grounding block appended after the
SNAPSHOT. For each present metric the block states the headline band, its
source (blood pressure on the ESH 2023 line, US/ESC framings as context
only), and where the user's value sits via the shared four-state
placement contract.
Framed strictly as general guidance: the block opens and closes with a
not-a-diagnosis caveat, never overrides the existing refusal/dose/drug-
level safety discipline, and carries no commercial brand name. Glucose
respects the diabetes opt-in — the tighter ADA management goal only when
the user has declared it, otherwise the general non-diabetic band.
The block is deterministic and inspectable: built purely from the
reference-range backbone over the same scalars the snapshot already
surfaces, so it can never cite a value or band the snapshot does not
carry.