BernhardBuckel caa7a937fd feat(labs): convert a reading into its marker's unit when the pair is known
Slice 2 of phase 3 of #1095. A reading that stated a unit other than its
marker's was refused. When the marker's analyte is known and the registry has the
pair, the three write paths now convert it instead: POST /api/labs, the OCR
commit and the document commit.

The converted value is stored at full precision in the marker's unit, with what
the report printed in the existing source_value and source_unit columns. The
report's own reference window is in the printed unit, so it is converted with the
value; otherwise the verdict would compare a converted value with an unconverted
window. A pair the registry does not have is still refused as before (the 422
now says why), as is a marker whose analyte is unknown.

The marker's key is filled the first time a reading needs it. The same scan
committed again is still a duplicate: a converted row holds the number in the
marker's unit, so the duplicate check also matches on what the report printed.
Editing the value of a converted reading clears the conversion record, because
the number is then the person's own.

The lab result DTO and the OpenAPI schemas (labs and the OCR commit) carry
converted, sourceValue and sourceUnit.

Refs #1095
2026-10-11 20:28:00 +02:00
BernhardBuckel d3916036c2 fix(labs): refuse a reading whose unit differs from its marker's
A numeric lab reading was stored with its value as received and the marker's
unit stamped on it, so 5.6 mmol/L against a marker kept in mg/dL became
5.6 mg/dL and read as far below range. Both the manual/API write and the
scan commit did this; nothing compared the two units.

- POST /api/labs returns 422 labs.unit.mismatch, with the marker's unit and
  the reading's unit in meta, and writes nothing. The unit is compared only
  when one was sent: on the biomarkerId path it may be omitted, and the
  marker's unit is then the stated one. A qualitative reading has no unit.
- The scan commit skips such a row with reason unit_mismatch, so the outcome
  reads partial or failed instead of a clean save, and the toast names the
  analytes concerned rather than saying "duplicates".
- The extract response carries the matched marker's unit. The review screen
  shows a calm badge on a row in another unit, starts it unticked like a
  duplicate, and treats it as a blocking error on the unit field if it is
  ticked anyway.
- A small lab-specific normaliser forgives spelling only: spacing, the micro
  prefix, the case of the litre, and a unit printed in capitals for a short
  list where capitals cannot mean another unit. Case is otherwise significant,
  so mIU/L and MIU/L, or g/L and G/L, are never merged.

The document-commit path already refuses a mismatch and is left as it is.
Readings stored wrongly before this cannot be identified, because the
original unit was never kept; they are not touched.

Adds EN and DE strings; the other locales are left to the maintainers. The
OpenAPI spec and the error-code catalogue carry the new code.

Fixes #1094
2026-10-03 15:44:51 +02:00