A converted reading's bounds move with its value, but the printed range text
stays in the unit the report used, and every reader preferred that text: the
list showed "Report range 3.9 to 5.5" beside 100.9 mg/dL, and the doctor
report and the FHIR referenceRange.text did the same. The text is still
stored verbatim. The range resolver now takes the reading's sourceUnit (as a
required field, so no reader can forget to select it) and, for a converted
reading, leaves the window's text empty so every surface states the converted
bounds in the marker's unit, and hands the printed text over separately with
its unit. The lab DTO carries it as printedReferenceText, and the note beside
a reading shows it as "as printed in mmol/L: ...".
Data never depends on AI. The Insights data reads no longer ask an AI
switch or the `insights` module (now only the AI analysis opt-out): ECG
list, detail and upload, rhythm events, derived scores, rule cards,
correlations and patterns, the baseline strip, health status, intraday
pulse, and the Today digest with its dismiss. Breathing screening moves
to the sleep module and lab changes to the labs module. Stored Coach
facts, conversations, message ratings and the seen stamp stay readable
and erasable while the Coach is unavailable. Cards now say
`provider: "rules"`.
Reads that mix data with model text answer 200, null the model text
and publish an `ai` state from the capability resolver, without warming
anything: comprehensive (`ai.briefing`, `ai.statusText`, `hasProvider`
from the presence probe), the derived assessment override, the period
narrative, nudge status, the seeded opener, about-me questions, the
workout paragraph, the pregenerate warm (`queued: false`), the Today
digest (lead, reaction line, check-in) and the dashboard briefing,
which is now applied per read after the snapshot cache. Hiding the
Coach no longer hides the briefing.
`insights/generate` GET and POST ask the `briefing` capability and
`insights/chat` POST the `coach` capability, with the typed refusal
envelope; a missing provider keeps the chat's `coach.provider.none`
frame and adds `reason`. The /coach page, the MCP ECG and intraday
tools and `aiAvailable` on the provider route follow the same answer.
An inventory of AI and data routes replaces the Coach gate inventory:
every route that asks a capability names it, and no data route asks.
Refs #975
A lab runs its own method on its own device, so the window a physician
evaluates a value against is the one printed next to it on that report,
not a catalog band averaged over every lab. Reading a report pulled the
value and dropped that range: the extraction asked for it, the commit
handed it to the biomarker resolver, and the resolver only uses it when
it mints a NEW marker. For every analyte the user already had — the
normal case after a first panel — the printed range was read and then
thrown away.
Add `sourceReferenceLow` / `sourceReferenceHigh` / `sourceReferenceText`
to `LabResult` and carry the range from the report to the reading. The
text is stored whether or not numbers can be read out of it, because
"bis 5,0" and "negativ" state a window too; a range that could not be
parsed is kept verbatim, never replaced with invented bounds.
`resolveEffectiveReferenceRange` is the one place the precedence lives:
the source window wins for that single reading, and the catalog stays
the net for readings without one. A printed string with no derivable
bound does not displace the catalog. Every surface that judges a
reading routes through it — the API verdict, the doctor report, the
insights blocks and per-marker assessment, the coach snapshot, the MCP
read and the FHIR `referenceRange` — so a value cannot read in range on
one surface and out on another.
The API keeps `referenceLow` / `referenceHigh` as the window in force,
so a client that reads only those two renders the right range and the
right verdict with no change of its own; the catalog band, the source
window, its origin and a divergence flag ride alongside for clients
that want to show both.
Read side: the chart draws the source window as a second, visually
distinct band with the reading it came from named beneath it, the
reading rows name the printed range and the catalog band where the two
disagree, and the doctor-report PDF prints the report's own string with
a footnote naming the saved range. Entry side: one optional field on
the lab form, folded away until asked for, and the printed range is
editable on the scan review screen.
The range parser covers the notations German and English reports
actually print — two-sided, one-sided, comma or dot decimals, thousands
separators, trailing units — reads units without ever converting them,
and refuses to guess on anything ambiguous.
Two things about the card that shows what changed since the last panel.
The comparison had no expiry. Someone whose newest panel is years old was
still reading "since your last panel" about a draw from another year — not
stale UI state but a stale sentence, and one the app kept repeating on the
overview every day.
The window is a year, applied to the data rather than to a per-user
dismissal. A year because routine panels are commonly drawn annually, so a
shorter window would hide a comparison that is genuinely the newest thing
somebody has for months out of every year, while past a year the wording
cannot be defended at all. Doing it on the data means nothing to
acknowledge, nothing to persist, no housekeeping asked of anyone, and one
answer for every client through the existing absent contract — the card
already un-mounts on it, and so does anything else reading that route.
Verified in both directions over the real endpoint.
The delta on the right was muted at the smaller size, the same typography
as the meta line under the analyte, so it optically hung off that lower
line and the row read as bottom-aligned even though it measures centred to
the pixel at every width. A delta is the number the row exists to report,
so it takes the content tier, and the cell states its own centring rather
than inheriting it.
The existing cases pinned their clock at the same time: fixed fixture days
against a relative window is a test that passes until a date in the future
and then fails for reasons unrelated to the code.
Add three read-only awareness cards to the Insights overview, each drawn
off an existing engine and each honest about empty state — the section
un-mounts rather than surfacing a husk.
- Health status: surfaces what is drifting from the user's own normal by
folding the personal-band deviations (coincident-deviation engine) with
the dated, sustained level shifts (changepoint detector) at
GET /api/insights/health-status. Awareness only, never a diagnosis.
- Breathing screening: summarises the last 30 nights of the per-night
sleep-breathing-disturbance index plus device-flagged events at
GET /api/insights/breathing-screening. Mirrors the device's own
classification and states plainly that it is a screening signal, not a
diagnosis — discuss with a clinician.
- Lab changes: pairs the two most-recent numeric lab panels and reports
each shared analyte's signed delta and reference-band standing at
GET /api/insights/labs-changes. Neutral framing only.
Each reshaping helper is pure and unit-tested for its present/absent
states. Register the three sections in the insights-layout universe so
they merge in as default-visible, wire them into the overview and the
edit-mode title map, add the query-factory keys, document the routes in
the OpenAPI contract, and translate every new string across all six
locales.