A lab runs its own method on its own device, so the window a physician
evaluates a value against is the one printed next to it on that report,
not a catalog band averaged over every lab. Reading a report pulled the
value and dropped that range: the extraction asked for it, the commit
handed it to the biomarker resolver, and the resolver only uses it when
it mints a NEW marker. For every analyte the user already had — the
normal case after a first panel — the printed range was read and then
thrown away.
Add `sourceReferenceLow` / `sourceReferenceHigh` / `sourceReferenceText`
to `LabResult` and carry the range from the report to the reading. The
text is stored whether or not numbers can be read out of it, because
"bis 5,0" and "negativ" state a window too; a range that could not be
parsed is kept verbatim, never replaced with invented bounds.
`resolveEffectiveReferenceRange` is the one place the precedence lives:
the source window wins for that single reading, and the catalog stays
the net for readings without one. A printed string with no derivable
bound does not displace the catalog. Every surface that judges a
reading routes through it — the API verdict, the doctor report, the
insights blocks and per-marker assessment, the coach snapshot, the MCP
read and the FHIR `referenceRange` — so a value cannot read in range on
one surface and out on another.
The API keeps `referenceLow` / `referenceHigh` as the window in force,
so a client that reads only those two renders the right range and the
right verdict with no change of its own; the catalog band, the source
window, its origin and a divergence flag ride alongside for clients
that want to show both.
Read side: the chart draws the source window as a second, visually
distinct band with the reading it came from named beneath it, the
reading rows name the printed range and the catalog band where the two
disagree, and the doctor-report PDF prints the report's own string with
a footnote naming the saved range. Entry side: one optional field on
the lab form, folded away until asked for, and the printed range is
editable on the scan review screen.
The range parser covers the notations German and English reports
actually print — two-sided, one-sided, comma or dot decimals, thousands
separators, trailing units — reads units without ever converting them,
and refuses to guess on anything ambiguous.
Swap the medication scheduling, inventory, illness, vorsorge, lab-OCR
and profile-birthdate date inputs from the native field to the
DateField primitive, which paints the chosen DMY/MDY/YMD/AUTO order
over an ISO yyyy-MM-dd value. The committed value contract, min/max
bounds and aria wiring are unchanged.
The extraction already self-scores each field; the review screen only
hinted at a shaky numeric value. Add a calm per-row low-confidence badge
when any tracked field scores below the threshold, including qualitative
rows that had no confidence cue. Informative secondary badge, no alarm
colour.
Replace the separate, capability-gated scan button with a single Add
menu: "Scan a document" (OCR) or "Add a value manually". The scan entry
appears only when the capability probe reports a usable mode, and routes
to native vision or local in-browser OCR (tesseract.js, lazy-loaded,
deu+eng, images only) per the resolved mode. Add the local-OCR opt-in
toggle to the Labs settings page with honest "less accurate — review
every value" copy.
Surface range confidence prominently on the OCR review screen for new
numeric biomarkers, where the extracted range becomes the catalog range:
flag low range-confidence or a missing range so the user verifies it.
Add the Scan a report entry to the Labs page, gated on the capability probe.
The review dialog uploads a photo or PDF, then shows each proposed reading for
per-row confirm, edit, or discard with duplicate, new-biomarker, and
low-confidence hints in the labs design language. Only confirmed rows commit.
Add the OCR query key and the six-locale strings.