resolveRestingPulseSeries returned the resting branch as soon as a
single RESTING_HEART_RATE row existed and never consulted the PULSE
proxy again. Since the retention fold began minting derived resting
rows for the days it folds, a proxy account carries derived rows for
old folded days and nothing but raw PULSE for the recent ones — so the
visible series stopped dead at the fold horizon.
Merge per day instead: a day with a resting row uses it, a day without
falls back to the proxy. which stays a three-value labelling signal and
reports proxy as soon as one point is estimated, so a partly-estimated
series is never labelled resting heart rate.
Widen the intraday baseline read to pull PULSE history when the newest
resting row is stale, not only when the rows are few — the count gate
alone pinned the baseline to the fold horizon.
One-shot prettier pass so the new format:check gate starts from a clean
baseline. Formatting only — no behaviour change. Generator-owned and
vendored artifacts stay untouched via .prettierignore.
Close four findings from the health-score audit:
- Hypotension cliff: the below-floor branch reused the over-target table,
so 1 mmHg under the clinical floor dropped from 100 to ~81 — a 19-point
discontinuity. A dedicated under-floor curve now starts at 100 AT the
floor and descends smoothly (floor-10->70, -20->45, -30->20), so the
score is continuous on both sides of every boundary on both axes.
- Rollup vs live divergence: the graded BP score weighed a high-variance
day 1:1 on the rollup path (one per-day-mean pair) but N:1 on the live
path (N per-event pairs), drifting the pillar by up to ~20 points
depending on DAY-bucket warmth. gradeBpScoreFromSeries now takes an
optional per-pair count; the rollup path passes perDayPairCount so both
paths produce the same score for the same data.
- Resting proxy degenerate days: a day with fewer than three PULSE
samples no longer contributes a resting estimate, so a lone workout
reading can't masquerade as resting HR.
- Pulse-status proxy day boundary: thread the user's timezone into the
resting-proxy day-key so it buckets identically to the targets route.
Fairness anchors unchanged (134/87 -> 57, 165/105 -> 22).
Every surface that applied a resting-pulse target judged the raw PULSE
series against a resting band. Apple Health maps all heart-rate samples
— including workout HR — onto PULSE, and the resting figure onto a
separate RESTING_HEART_RATE type. A single workout emits hundreds of
expected-high samples, so the resting-target evaluation read a large
share "outside target" and tanked the in-target % / consistency even
when the clean resting series averaged a healthy figure.
Judge the resting band against a resting series. A shared helper prefers
RESTING_HEART_RATE; when the user has none it derives a proxy from the
low percentile of each day's PULSE samples, so a dense workout burst
sitting in the upper tail cannot drag the resting estimate up. Applied
to the resting-pulse tile + its consistency strip, the pulse in-target %
in the assessment snapshot, and the dashboard / sub-page classification.
Raw heart rate, where it is merely charted, no longer carries the
resting-band overlay. The doctor report is unchanged — it reports raw
heart-rate stats factually, with no resting-target judgment to mislead.