mirror of
https://github.com/MBombeck/HealthLog.git
synced 2026-11-18 08:02:12 +00:00
fix(coach): state reference and time-in-range bands in the reader's units
The reference grounding printed the fasting glucose bands in mg/dL and the body-temperature band in °C, and the system prompt described time in range as 70-180 mg/dL. For a reader on mmol/L or Fahrenheit the model was handed one quantity in two units: the glucose block in mmol/L, the band beside it in mg/dL. The grounding block now takes both unit preferences and prints the general, the diabetes goal and the temperature band in them, while the placement is still classified on the canonical value. The glucose block carries the time-in-range band in its own unit, and the prompt points the model at it instead of naming a unit. Refs #1067
This commit is contained in:
1 parent
6dbf57f4f4
commit
d1b2539b1f
8 files changed
+195
-15
No files matched your search
@@ -85,6 +85,11 @@ const TBR_LEVEL1_MAX = 70; // low: G < 70 (level-1 sub-band is 54–69)
|
||||
const TAR_LEVEL1_MIN = 180; // high: G > 180 (level-1 sub-band is 181–250)
|
||||
const TAR_LEVEL2_MIN = 250; // very high: G > 250
|
||||
// Time-in-range target band is [70, 180] inclusive.
|
||||
/** The time-in-range band, mg/dL, inclusive at both ends. */
|
||||
export const TIME_IN_RANGE_MGDL = {
|
||||
low: TBR_LEVEL1_MAX,
|
||||
high: TAR_LEVEL1_MIN,
|
||||
} as const;
|
||||
|
||||
/** Monnier 2017 variability cutoff: CV% ≥ 36 is "unstable". */
|
||||
export const CV_INSTABILITY_THRESHOLD = 36;
|
||||
|
||||
Reference in new issue
Block a user