docs(labs): say what a later entered-in-error status does to a stored result

A Health Records result the provider later marks entered in error is
skipped as withdrawn, but a reading already stored from an earlier
version stays until it is deleted in HealthLog. Say so in the changelog,
the import guide and the batch route's contract, and bring the guide's
archive limits and lab notes in line with the current reader.
This commit is contained in:
Marc-André Bombeck committed 2026-11-17 21:28:57 +01:00
1 parent 6aad42a384
commit b415d394ae
4 files changed
+36 -15

No files matched your search

+7 -6
View File
@@ -78308,12 +78308,13 @@ components:
holds it, under the same identity (deleted readings included, also once the reading or its whole marker is gone,
so a deleted result stays deleted) or as the same reading on the same day from another source. `skipped`: not a
reading HealthLog keeps, with `reason` `not_observation` | `not_lab` (no category names a lab; a code, display
or text containing `lab` in any case counts) | `not_final` (preliminary; it is taken once final) | `withdrawn` |
`panel_header` | `no_value` | `unsupported_value` | `no_date` | `future_date` | `invalid_date` | `too_large` (a
resource over 256 KiB). `failed`: a reading that could not be stored, with `reason` `missing_unit` (a number
without a unit; a specific gravity, a pH or an INR, known by its LOINC code, is read as the unity `1` instead) |
`unit_mismatch` (the account's marker is in a unit this one does not convert into) | `text_too_long` |
`write_failed` (transient: send it again)."
or text containing `lab` in any case counts) | `not_final` (preliminary; it is taken once final) | `withdrawn`
(entered in error or cancelled; a reading already stored from an earlier version of the result is not removed,
delete it through `DELETE /api/labs/{id}`) | `panel_header` | `no_value` | `unsupported_value` | `no_date` |
`future_date` | `invalid_date` | `too_large` (a resource over 256 KiB). `failed`: a reading that could not be
stored, with `reason` `missing_unit` (a number without a unit; a specific gravity, a pH or an INR, known by its
LOINC code, is read as the unity `1` instead) | `unit_mismatch` (the account's marker is in a unit this one does
not convert into) | `text_too_long` | `write_failed` (transient: send it again)."
LabOverviewEnvelope:
type: object
properties: