mirror of
https://github.com/MBombeck/HealthLog.git
synced 2026-11-18 16:12:11 +00:00
fix(medications): apply the post-opening clock only where a container has one
A supply container went EXPIRED 30 days after its first use no matter what kind of container it was. That window exists because puncturing an injection pen exposes its contents and the product information caps how long the rest stays usable; a blister of tablets has no such limit, every tablet sits in its own sealed cavity, and pressing the first one out says nothing about the rest. The state machine never read `containerType`, so a tablet pack opened five weeks ago had its remaining stock written off. The clock now keys off the container kind. PEN and AMPOULE carry it: both are a single sealed reservoir that the first dose breaches. BLISTER, INHALER, BOTTLE and OTHER do not: their units stay individually sealed, or the arrangement is simply unknown, and a fixed 30 days would be a number nobody entered. The printed expiry still applies to every kind, so an unknown container is not an unbounded one. `computeExpiresAt` takes the kind too, so a clock-less container with no printed date now persists no `expiresAt` at all and the daily expire scan never sees it. The per-item PATCH gains a way back out: `markAsFirstUseAt` accepts null and clears the opening date, which is the correction a container needs after the intake hook auto-opened it from a back-dated dose. Also drops `daysRemainingInUse`. It had no caller anywhere in the tree and its docblock described a chip that does not exist.
This commit is contained in:
1 parent
c941e7e5cb
commit
a1dbd9c831
11 files changed
+394
-179
No files matched your search
+23
-13
@@ -12943,8 +12943,9 @@ components:
|
||||
description: Units the container ships with (tablets / ampoules / puffs; 1–1000, fractional allowed for split-pill
|
||||
packs). Dose-derived readouts divide by the medication's `unitsPerDose`.
|
||||
containerType:
|
||||
description: Kind of physical container (PEN / AMPOULE / BLISTER / INHALER / BOTTLE / OTHER). Display-level only;
|
||||
defaults to OTHER.
|
||||
description: Kind of physical container (PEN / AMPOULE / BLISTER / INHALER / BOTTLE / OTHER). Defaults to OTHER. PEN and
|
||||
AMPOULE are the sealed reservoirs the first dose breaches, so they carry a 30-day post-opening window; every
|
||||
other kind expires only on its printed date.
|
||||
type: string
|
||||
enum:
|
||||
- PEN
|
||||
@@ -12991,11 +12992,15 @@ components:
|
||||
type: object
|
||||
properties:
|
||||
markAsFirstUseAt:
|
||||
description: Manually start the 30-day in-use clock (the user opened the container without logging an intake). ACTIVE
|
||||
flips to IN_USE; a backdated instant whose window already lapsed lands EXPIRED.
|
||||
type: string
|
||||
format: date-time
|
||||
pattern: ^(?:(?:\d\d[2468][048]|\d\d[13579][26]|\d\d0[48]|[02468][048]00|[13579][26]00)-02-29|\d{4}-(?:(?:0[13578]|1[02])-(?:0[1-9]|[12]\d|3[01])|(?:0[469]|11)-(?:0[1-9]|[12]\d|30)|(?:02)-(?:0[1-9]|1\d|2[0-8])))T(?:(?:[01]\d|2[0-3]):[0-5]\d(?::[0-5]\d(?:\.\d+)?)?(?:Z|([+-](?:[01]\d|2[0-3]):[0-5]\d)))$
|
||||
description: Opening date of the container (the user opened it without logging an intake). ACTIVE flips to IN_USE.
|
||||
`null` clears it — the container reads as unopened again, which is how a wrongly auto-opened row is
|
||||
corrected. For a PEN or an AMPOULE this also starts / stops the 30-day in-use clock; other container kinds
|
||||
carry no such clock and expire only on their printed date.
|
||||
anyOf:
|
||||
- type: string
|
||||
format: date-time
|
||||
pattern: ^(?:(?:\d\d[2468][048]|\d\d[13579][26]|\d\d0[48]|[02468][048]00|[13579][26]00)-02-29|\d{4}-(?:(?:0[13578]|1[02])-(?:0[1-9]|[12]\d|3[01])|(?:0[469]|11)-(?:0[1-9]|[12]\d|30)|(?:02)-(?:0[1-9]|1\d|2[0-8])))T(?:(?:[01]\d|2[0-3]):[0-5]\d(?::[0-5]\d(?:\.\d+)?)?(?:Z|([+-](?:[01]\d|2[0-3]):[0-5]\d)))$
|
||||
- type: "null"
|
||||
markAsUsedUp:
|
||||
description: "Terminal override: zero the remaining units and mark the container USED_UP (physically discarded)."
|
||||
type: boolean
|
||||
@@ -20474,8 +20479,9 @@ components:
|
||||
- IN_USE
|
||||
- EXPIRED
|
||||
- USED_UP
|
||||
description: Container lifecycle state. ACTIVE = unopened; IN_USE = opened (30-day in-use clock running); EXPIRED =
|
||||
printed expiry or in-use window lapsed with units left; USED_UP = drained (terminal).
|
||||
description: Container lifecycle state. ACTIVE = unopened; IN_USE = opened (on a PEN / AMPOULE the 30-day in-use clock
|
||||
is running); EXPIRED = printed expiry lapsed, or the in-use window lapsed on a clock-bearing container, with
|
||||
units left; USED_UP = drained (terminal).
|
||||
containerType:
|
||||
type: string
|
||||
enum:
|
||||
@@ -20485,8 +20491,10 @@ components:
|
||||
- INHALER
|
||||
- BOTTLE
|
||||
- OTHER
|
||||
description: Kind of physical container (PEN / AMPOULE / BLISTER / INHALER / BOTTLE / OTHER). Display-level
|
||||
classification; defaults to OTHER.
|
||||
description: Kind of physical container (PEN / AMPOULE / BLISTER / INHALER / BOTTLE / OTHER); defaults to OTHER. PEN and
|
||||
AMPOULE are the sealed reservoirs the first dose breaches, so opening one starts a 30-day post-opening
|
||||
window; BLISTER / INHALER / BOTTLE / OTHER hold individually sealed units and expire only on their printed
|
||||
date.
|
||||
unitsTotal:
|
||||
anyOf:
|
||||
- type: number
|
||||
@@ -20509,14 +20517,16 @@ components:
|
||||
format: date-time
|
||||
pattern: ^(?:(?:\d\d[2468][048]|\d\d[13579][26]|\d\d0[48]|[02468][048]00|[13579][26]00)-02-29|\d{4}-(?:(?:0[13578]|1[02])-(?:0[1-9]|[12]\d|3[01])|(?:0[469]|11)-(?:0[1-9]|[12]\d|30)|(?:02)-(?:0[1-9]|1\d|2[0-8])))T(?:(?:[01]\d|2[0-3]):[0-5]\d(?::[0-5]\d(?:\.\d+)?)?(?:Z|([+-](?:[01]\d|2[0-3]):[0-5]\d)))$
|
||||
- type: "null"
|
||||
description: Instant the container was first used. NULL until opened; starts the 30-day in-use clock.
|
||||
description: Instant the container was first used. NULL until opened. On a PEN / AMPOULE it starts the 30-day in-use
|
||||
clock; on the other kinds it only records that the pack is open.
|
||||
expiresAt:
|
||||
anyOf:
|
||||
- type: string
|
||||
format: date-time
|
||||
pattern: ^(?:(?:\d\d[2468][048]|\d\d[13579][26]|\d\d0[48]|[02468][048]00|[13579][26]00)-02-29|\d{4}-(?:(?:0[13578]|1[02])-(?:0[1-9]|[12]\d|3[01])|(?:0[469]|11)-(?:0[1-9]|[12]\d|30)|(?:02)-(?:0[1-9]|1\d|2[0-8])))T(?:(?:[01]\d|2[0-3]):[0-5]\d(?::[0-5]\d(?:\.\d+)?)?(?:Z|([+-](?:[01]\d|2[0-3]):[0-5]\d)))$
|
||||
- type: "null"
|
||||
description: Persisted MIN(firstUseAt + 30 days, printedExpiry). NULL when neither clock has started.
|
||||
description: Persisted MIN(firstUseAt + 30 days, printedExpiry) for a clock-bearing container (PEN / AMPOULE), else
|
||||
printedExpiry alone. NULL when no deadline applies — an opened blister with no printed date has none.
|
||||
printedExpiry:
|
||||
anyOf:
|
||||
- type: string
|
||||
|
||||
Reference in new issue