docs(openapi): give rhythm-events its own six-value classification enum
GET /api/insights/rhythm-events was never in the spec, so a client had nothing to generate a type from but the three-value ECG classification next door — reusing it would drop VERY_LOW / FIRED. Register the route with its own RhythmEventClassification carrying all six RhythmClassification values; the ECG enum stays untouched at three.
This commit is contained in:
1 parent
d7badf1512
commit
9a5206ee5f
3 files changed
+236
-1
No files matched your search
@@ -7743,6 +7743,31 @@ paths:
|
||||
$ref: "#/components/schemas/ErrorEnvelope"
|
||||
"422": *a3
|
||||
"429": *a4
|
||||
/api/insights/rhythm-events:
|
||||
get:
|
||||
tags:
|
||||
- Insights
|
||||
summary: Device-flagged rhythm/HR/steadiness event timeline
|
||||
description: "v1.10.0 (WX-B) — the authenticated user's timeline of device-flagged EVENT rows: irregular-rhythm /
|
||||
high-HR / low-HR / walking-steadiness / breathing-disturbance notifications the user's wearable (Apple Watch /
|
||||
Withings ScanWatch) already produced and synced. AWARENESS / SCREENING of the DEVICE's own decision — HealthLog
|
||||
stores and reflects ONLY the classification result the device's certified on-device algorithm emitted, verbatim;
|
||||
it never re-classifies and never produces a HealthLog diagnosis. `classification` carries the full six-value
|
||||
verdict set (the three ECG verdicts plus the two walking-steadiness severities plus the neutral FIRED verdict) —
|
||||
a distinct, wider enum than the three-value one on GET /api/insights/ecg. Data-availability-gated: an account
|
||||
with no event rows returns `hasEvents: false`. Module-gated on `insights` and the operator `insightStatus`
|
||||
assistant surface; no LLM call. Auth via cookie or Bearer."
|
||||
responses:
|
||||
"200":
|
||||
description: The device-flagged event timeline (possibly empty).
|
||||
content:
|
||||
application/json:
|
||||
schema:
|
||||
$ref: "#/components/schemas/RhythmEventsResponseEnvelope"
|
||||
"401": *a1
|
||||
"403": *a5
|
||||
"422": *a3
|
||||
"429": *a4
|
||||
/api/insights/correlations:
|
||||
get:
|
||||
tags:
|
||||
@@ -28508,6 +28533,119 @@ components:
|
||||
narrowed in the query where — a foreign / unknown id 404s. The waveform is AES-256-GCM at rest, decrypted
|
||||
through the fail-closed codec. HealthLog does not interpret the trace, measure intervals, annotate beats, or
|
||||
emit a verdict of its own. no-store.
|
||||
RhythmEventsResponseEnvelope:
|
||||
type: object
|
||||
properties:
|
||||
data:
|
||||
$ref: "#/components/schemas/RhythmEventsResponse"
|
||||
error:
|
||||
type: "null"
|
||||
meta:
|
||||
type: object
|
||||
properties:
|
||||
requestId:
|
||||
type: string
|
||||
additionalProperties: false
|
||||
required:
|
||||
- data
|
||||
- error
|
||||
additionalProperties: false
|
||||
RhythmEventsResponse:
|
||||
type: object
|
||||
properties:
|
||||
events:
|
||||
type: array
|
||||
items:
|
||||
$ref: "#/components/schemas/RhythmEventListItem"
|
||||
description: The user's device-flagged events, newest first (capped at 200).
|
||||
hasEvents:
|
||||
type: boolean
|
||||
description: False for an account with no event rows — the client un-mounts the whole surface (data-availability floor).
|
||||
required:
|
||||
- events
|
||||
- hasEvents
|
||||
additionalProperties: false
|
||||
description: Timeline of device-flagged EVENT rows (irregular-rhythm / high-HR / low-HR / walking-steadiness /
|
||||
breathing-disturbance) the user's wearable (Apple Watch / Withings ScanWatch) already produced and synced.
|
||||
AWARENESS / SCREENING of the DEVICE's own decision — HealthLog stores and reflects the classification result
|
||||
verbatim, never a raw waveform, and never re-classifies. Read-only; no LLM call.
|
||||
RhythmEventListItem:
|
||||
type: object
|
||||
properties:
|
||||
id:
|
||||
type: string
|
||||
description: Measurement row id (cuid).
|
||||
type:
|
||||
type: string
|
||||
enum:
|
||||
- IRREGULAR_RHYTHM_NOTIFICATION
|
||||
- HIGH_HEART_RATE_EVENT
|
||||
- LOW_HEART_RATE_EVENT
|
||||
- WALKING_STEADINESS_EVENT
|
||||
- BREATHING_DISTURBANCE_EVENT
|
||||
description: The HealthKit category the device flagged. IRREGULAR_RHYTHM_NOTIFICATION
|
||||
(`HKCategoryTypeIdentifierIrregularHeartRhythmEvent` + ScanWatch AFib screening), HIGH_HEART_RATE_EVENT /
|
||||
LOW_HEART_RATE_EVENT (a sustained heart rate above / below the user's configured threshold while apparently
|
||||
inactive), WALKING_STEADINESS_EVENT (`HKCategoryTypeIdentifierAppleWalkingSteadinessEvent`; the severity
|
||||
rides in `classification`), BREATHING_DISTURBANCE_EVENT (`HKCategoryTypeIdentifierSleepApneaEvent` +
|
||||
`AppleSleepingBreathingDisturbances`, an elevated breathing-disturbance / possible sleep-apnea screening
|
||||
signal).
|
||||
classification:
|
||||
anyOf:
|
||||
- type: string
|
||||
enum:
|
||||
- IRREGULAR
|
||||
- NOT_DETECTED
|
||||
- INCONCLUSIVE
|
||||
- LOW
|
||||
- VERY_LOW
|
||||
- FIRED
|
||||
- type: "null"
|
||||
description: The RECORDING DEVICE's own verdict, surfaced verbatim. IRREGULAR / NOT_DETECTED / INCONCLUSIVE are the
|
||||
ECG-style rhythm verdicts (device flagged a possible irregular rhythm / algorithm ran and found nothing /
|
||||
signal too poor to classify) and occur on an `IRREGULAR_RHYTHM_NOTIFICATION` row. LOW / VERY_LOW are
|
||||
walking-steadiness severities and occur on a `WALKING_STEADINESS_EVENT` row. FIRED is the neutral "event
|
||||
occurred" verdict with no severity gradient, and occurs on a `HIGH_HEART_RATE_EVENT` /
|
||||
`LOW_HEART_RATE_EVENT` / `BREATHING_DISTURBANCE_EVENT` row. Null when the source reported none. HealthLog
|
||||
never re-classifies — this is the device's certified on-device result. Distinct from
|
||||
`EcgRecordingListItem.classification` / `EcgDetailResponse.classification` above, which are scoped to the
|
||||
three ECG-only values.
|
||||
occurredAt:
|
||||
type: string
|
||||
format: date-time
|
||||
pattern: ^(?:(?:\d\d[2468][048]|\d\d[13579][26]|\d\d0[48]|[02468][048]00|[13579][26]00)-02-29|\d{4}-(?:(?:0[13578]|1[02])-(?:0[1-9]|[12]\d|3[01])|(?:0[469]|11)-(?:0[1-9]|[12]\d|30)|(?:02)-(?:0[1-9]|1\d|2[0-8])))T(?:(?:[01]\d|2[0-3]):[0-5]\d(?::[0-5]\d(?:\.\d+)?)?(?:Z|([+-](?:[01]\d|2[0-3]):[0-5]\d)))$
|
||||
description: Device-reported event time (`measuredAt`).
|
||||
source:
|
||||
type: string
|
||||
enum:
|
||||
- MANUAL
|
||||
- WITHINGS
|
||||
- IMPORT
|
||||
- APPLE_HEALTH
|
||||
- COMPUTED
|
||||
- WHOOP
|
||||
- FITBIT
|
||||
- NIGHTSCOUT
|
||||
- POLAR
|
||||
- OURA
|
||||
- TELEGRAM
|
||||
- MCP
|
||||
- GOOGLE_HEALTH
|
||||
- STRAVA
|
||||
deviceType:
|
||||
anyOf:
|
||||
- type: string
|
||||
- type: "null"
|
||||
description: Device class that reported the event (`watch | band | ring | phone | scale | other | unknown`); null when
|
||||
the source omitted it (treated as `unknown`).
|
||||
required:
|
||||
- id
|
||||
- type
|
||||
- classification
|
||||
- occurredAt
|
||||
- source
|
||||
- deviceType
|
||||
additionalProperties: false
|
||||
CorrelationDiscoveryResponseEnvelope:
|
||||