fix(labs): never present a converted reading's printed range in the wrong unit
A converted reading's bounds move with its value, but the printed range text stays in the unit the report used, and every reader preferred that text: the list showed "Report range 3.9 to 5.5" beside 100.9 mg/dL, and the doctor report and the FHIR referenceRange.text did the same. The text is still stored verbatim. The range resolver now takes the reading's sourceUnit (as a required field, so no reader can forget to select it) and, for a converted reading, leaves the window's text empty so every surface states the converted bounds in the marker's unit, and hands the printed text over separately with its unit. The lab DTO carries it as printedReferenceText, and the note beside a reading shows it as "as printed in mmol/L: ...".
This commit is contained in:
1 parent
cc0313c955
commit
47a91d6922
29 files changed
+365
-20
No files matched your search
@@ -80,6 +80,7 @@ const labResultRow = z
|
||||
sourceReferenceLow: z.number().nullable(),
|
||||
sourceReferenceHigh: z.number().nullable(),
|
||||
sourceReferenceText: z.string().nullable(),
|
||||
printedReferenceText: z.string().nullable(),
|
||||
referenceOrigin: referenceOriginEnum,
|
||||
referenceDivergesFromCatalog: z.boolean(),
|
||||
takenAt: z.string(),
|
||||
@@ -92,7 +93,7 @@ const labResultRow = z
|
||||
.meta({
|
||||
id: "LabResult",
|
||||
description:
|
||||
"A stored lab result. Exactly one of `value` (numeric) or `valueText` (qualitative, e.g. \"negativ\") is non-null; `rangeStatus` is always `unknown` for a qualitative row (no number to classify). `biomarkerId` links the user-scoped catalog marker (null for legacy free-text rows); when linked, `analyte` / `unit` are RESOLVED server-side from the Biomarker.\n\nThree reference windows ride on the row and the server says which one applies. `referenceLow` / `referenceHigh` are the window IN FORCE and the one `rangeStatus` was computed from — read these to render the range and you are correct without doing any resolution of your own. `sourceReferenceLow` / `sourceReferenceHigh` / `sourceReferenceText` are the range this reading's own report printed (the text verbatim, kept even when no numbers could be read out of it). `catalogReferenceLow` / `catalogReferenceHigh` are the Biomarker band. `referenceOrigin` names the winner and `referenceDivergesFromCatalog` is true when the report's window and the catalog band state different limits — a surface showing only one of the two is showing a partial answer. The client renders these values and never recomputes the range. `converted` is true when the stored `value` was converted into the marker's `unit` from another unit; `sourceValue` and `sourceUnit` are then what the report printed (full precision, round for display), and the report's own window was converted with it. A reading stored as stated has `converted: false` and two nulls. The encrypted note is never echoed in list rows; `hasNote` flags its presence and the single-resource GET returns the decrypted `note`.",
|
||||
"A stored lab result. Exactly one of `value` (numeric) or `valueText` (qualitative, e.g. \"negativ\") is non-null; `rangeStatus` is always `unknown` for a qualitative row (no number to classify). `biomarkerId` links the user-scoped catalog marker (null for legacy free-text rows); when linked, `analyte` / `unit` are RESOLVED server-side from the Biomarker.\n\nThree reference windows ride on the row and the server says which one applies. `referenceLow` / `referenceHigh` are the window IN FORCE and the one `rangeStatus` was computed from — read these to render the range and you are correct without doing any resolution of your own. `sourceReferenceLow` / `sourceReferenceHigh` / `sourceReferenceText` are the range this reading's own report printed (the text verbatim, kept even when no numbers could be read out of it). `catalogReferenceLow` / `catalogReferenceHigh` are the Biomarker band. `referenceOrigin` names the winner and `referenceDivergesFromCatalog` is true when the report's window and the catalog band state different limits — a surface showing only one of the two is showing a partial answer. The client renders these values and never recomputes the range. `converted` is true when the stored `value` was converted into the marker's `unit` from another unit; `sourceValue` and `sourceUnit` are then what the report printed (full precision, round for display), and the report's own window was converted with it: `sourceReferenceLow` / `sourceReferenceHigh` are then in the marker's `unit`. The printed range text is not converted and stays in `sourceUnit`, so for a converted reading `sourceReferenceText` is null and the verbatim text is in `printedReferenceText` instead, never mixed with the converted numbers. A reading stored as stated has `converted: false`, two nulls and a null `printedReferenceText`. The encrypted note is never echoed in list rows; `hasNote` flags its presence and the single-resource GET returns the decrypted `note`.",
|
||||
});
|
||||
|
||||
const labResultDetail = labResultRow
|
||||
|
||||
@@ -129,6 +129,7 @@ const committedRow = z
|
||||
sourceReferenceLow: z.number().nullable(),
|
||||
sourceReferenceHigh: z.number().nullable(),
|
||||
sourceReferenceText: z.string().nullable(),
|
||||
printedReferenceText: z.string().nullable(),
|
||||
referenceOrigin: z.enum(["source", "catalog", "none"]),
|
||||
referenceDivergesFromCatalog: z.boolean(),
|
||||
takenAt: z.string(),
|
||||
@@ -141,7 +142,7 @@ const committedRow = z
|
||||
.meta({
|
||||
id: "OcrCommittedLabResult",
|
||||
description:
|
||||
"A written reading. Its reference window resolves exactly as it does on `/api/labs` — see `LabResult`. `converted`, `sourceValue` and `sourceUnit` say when the row's unit was converted into its marker's and what the report printed.",
|
||||
"A written reading. Its reference window resolves exactly as it does on `/api/labs` — see `LabResult`. `converted`, `sourceValue` and `sourceUnit` say when the row's unit was converted into its marker's and what the report printed; for a converted row the printed range text is in `printedReferenceText` (in `sourceUnit`) and `sourceReferenceText` is null.",
|
||||
});
|
||||
|
||||