fix(labs): never present a converted reading's printed range in the wrong unit
A converted reading's bounds move with its value, but the printed range text stays in the unit the report used, and every reader preferred that text: the list showed "Report range 3.9 to 5.5" beside 100.9 mg/dL, and the doctor report and the FHIR referenceRange.text did the same. The text is still stored verbatim. The range resolver now takes the reading's sourceUnit (as a required field, so no reader can forget to select it) and, for a converted reading, leaves the window's text empty so every surface states the converted bounds in the marker's unit, and hands the printed text over separately with its unit. The lab DTO carries it as printedReferenceText, and the note beside a reading shows it as "as printed in mmol/L: ...".
This commit is contained in:
1 parent
cc0313c955
commit
47a91d6922
29 files changed
+365
-20
No files matched your search
@@ -9,6 +9,7 @@ const NO_SOURCE = {
|
||||
sourceReferenceLow: null,
|
||||
sourceReferenceHigh: null,
|
||||
sourceReferenceText: null,
|
||||
sourceUnit: null,
|
||||
};
|
||||
|
||||
describe("resolveEffectiveReferenceRange", () => {
|
||||
@@ -36,6 +37,7 @@ describe("resolveEffectiveReferenceRange", () => {
|
||||
sourceReferenceLow: 3.9,
|
||||
sourceReferenceHigh: 5.4,
|
||||
sourceReferenceText: "3,9 - 5,4",
|
||||
sourceUnit: null,
|
||||
});
|
||||
expect(eff).toMatchObject({
|
||||
low: 3.9,
|
||||
@@ -53,6 +55,7 @@ describe("resolveEffectiveReferenceRange", () => {
|
||||
sourceReferenceLow: 3.5,
|
||||
sourceReferenceHigh: 5,
|
||||
sourceReferenceText: "3,5 - 5,0",
|
||||
sourceUnit: null,
|
||||
});
|
||||
expect(eff.origin).toBe("source");
|
||||
expect(eff.divergesFromCatalog).toBe(false);
|
||||
@@ -65,6 +68,7 @@ describe("resolveEffectiveReferenceRange", () => {
|
||||
sourceReferenceLow: null,
|
||||
sourceReferenceHigh: 4.2,
|
||||
sourceReferenceText: "< 4,2",
|
||||
sourceUnit: null,
|
||||
});
|
||||
expect(eff).toMatchObject({
|
||||
low: null,
|
||||
@@ -81,6 +85,7 @@ describe("resolveEffectiveReferenceRange", () => {
|
||||
sourceReferenceLow: null,
|
||||
sourceReferenceHigh: null,
|
||||
sourceReferenceText: "negativ",
|
||||
sourceUnit: null,
|
||||
});
|
||||
expect(eff).toMatchObject({
|
||||
low: 3.5,
|
||||
@@ -96,12 +101,57 @@ describe("resolveEffectiveReferenceRange", () => {
|
||||
sourceReferenceLow: 3.9,
|
||||
sourceReferenceHigh: 5.4,
|
||||
sourceReferenceText: "3,9 - 5,4",
|
||||
sourceUnit: null,
|
||||
});
|
||||
expect(eff.origin).toBe("source");
|
||||
expect(eff.divergesFromCatalog).toBe(false);
|
||||
});
|
||||
});
|
||||
|
||||
describe("a converted reading's printed text", () => {
|
||||
// 5.6 mmol/L stored as mg/dL, with the printed 3.9 to 5.5 mmol/L window
|
||||
// converted alongside; the text stays as the report printed it.
|
||||
const CONVERTED = {
|
||||
sourceReferenceLow: 3.9 * 18.0182,
|
||||
sourceReferenceHigh: 5.5 * 18.0182,
|
||||
sourceReferenceText: "3,9 - 5,5",
|
||||
sourceUnit: "mmol/L",
|
||||
};
|
||||
|
||||
it("is never the window's text, so no statement mixes two units", () => {
|
||||
const eff = resolveEffectiveReferenceRange(70, 100, CONVERTED);
|
||||
expect(eff.origin).toBe("source");
|
||||
expect(eff.low).toBeCloseTo(70.27, 2);
|
||||
expect(eff.sourceText).toBeNull();
|
||||
});
|
||||
|
||||
it("is kept as evidence with the unit it is written in", () => {
|
||||
const eff = resolveEffectiveReferenceRange(70, 100, CONVERTED);
|
||||
expect(eff.printed).toEqual({ text: "3,9 - 5,5", unit: "mmol/L" });
|
||||
});
|
||||
|
||||
it("stays the window's text for a reading stored as stated", () => {
|
||||
const eff = resolveEffectiveReferenceRange(70, 100, {
|
||||
...CONVERTED,
|
||||
sourceUnit: null,
|
||||
});
|
||||
expect(eff.sourceText).toBe("3,9 - 5,5");
|
||||
expect(eff.printed).toBeNull();
|
||||
});
|
||||
|
||||
it("moves an unreadable printed text the same way", () => {
|
||||
const eff = resolveEffectiveReferenceRange(70, 100, {
|
||||
sourceReferenceLow: null,
|
||||
sourceReferenceHigh: null,
|
||||
sourceReferenceText: "siehe Befund",
|
||||
sourceUnit: "mmol/L",
|
||||
});
|
||||
expect(eff.origin).toBe("catalog");
|
||||
expect(eff.sourceText).toBeNull();
|
||||
expect(eff.printed).toEqual({ text: "siehe Befund", unit: "mmol/L" });
|
||||
});
|
||||
});
|
||||
|
||||
describe("classifyAgainstEffectiveRange", () => {
|
||||
it("judges a reading by the source window, not the catalog band", () => {
|
||||
// 5.2 sits inside the catalog band (3.5–5.0 would call it high) but the
|
||||
@@ -110,6 +160,7 @@ describe("classifyAgainstEffectiveRange", () => {
|
||||
sourceReferenceLow: 3.9,
|
||||
sourceReferenceHigh: 5.4,
|
||||
sourceReferenceText: "3,9 - 5,4",
|
||||
sourceUnit: null,
|
||||
});
|
||||
expect(classifyAgainstEffectiveRange(5.2, eff)).toBe("in-range");
|
||||
expect(classifyAgainstEffectiveRange(3.7, eff)).toBe("below");
|
||||
|
||||
Reference in new issue